4.2.60 Full Stack Sensor
(See “Exit Upper Chute Assembly” on page -279)
4.2.60.1 Removal
1. Remove the Fuser Full Cover. (“Fuser Full Cover” on page -138)
2. Disconnect J133 and remove the wire harness from the harness
clips.
3. Squeeze the latches to unlock the Full Stack Sensor, and remove
the Sensor from the Offset Assembly.
Figure 4-75. Removal of Full Stack Sensor
4.2.60.2 Installation
1. Reinstall the Full Stack Sensor by pressing the Sensor latches into
the cutouts in the Offset Assembly.
2. Reconnect J133 and secure the wire harness under the harness
clips.
3. Reinstall the Fuser Full Cover. (“Fuser Full Cover” on page -138)
C H E C K
P O I N T
Make sure you install the Sensor with the wire
positioned to the rear of the Offset Assembly, and
the Sensor actuator moving freely through the
cutout below the Sensor.