d
Adjust the focus if necessary, by opening the air filter cover on the
side of the projector and sliding the focus lever.
e
Press the [Enter] button to select
Yes
.
A pattern appears then disappears, and the system is calibrated. If
you see a message that calibration failed, you need to calibrate
manually.
The cursor location and pen position should match after calibration. If not,
you may need to calibrate manually.
Calibrating Manually
If the cursor location and pen position do not match after auto calibration,
you can calibrate manually.
a
Press the [Menu] button, select the
Extended
menu, and press
the [Enter] button.
b
Select the
Easy Interactive Function
setting and press the [Enter]
button.
c
Select
Manual Calibration
and press the [Enter] button.