AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
289
Confidential
SENSOR ASSY CRU (C), (M), (Y)
1.
Remove the screw (silver, self-tapping, 10 mm) that secures the SENSOR ASSY CRU to the main unit.
2.
Remove the SENSOR ASSY CRU from the main unit.
3.
Disconnect the connector on the SENSOR ASSY CRU.
A D
Kmy03036EB
1)
2)
3)
SENSOR ASSY CRU (C)
SENSOR ASSY CRU (M)
SENSOR ASSY CRU (Y)
CONNECTOR CRUM
C H E C K
P O I N T
There are four CONNECTOR CRUMs and they can be removed in the same manner.
1.
Slide the CONNECTOR CRUM toward right and release its groove from the main unit.
2.
Disconnect the connector of the CONNECTOR CRUM and remove the CONNECTOR CRUM.
A
Kmy03034EB
1)-2
2)
1)-1
CONNECTOR CRUM