AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
295
Confidential
2.
Remove the two screws (silver, washer, 6 mm) that secure the two harnesses coming out of the HVPS.
Secure the red harness to the upper side and the white harness to the downside of the
HVPS.
3.
Remove the five screws (silver, self-tapping, 10 mm) that secure the HVPS to the main unit.
4.
Remove the three screws (silver, 6 mm) that secure the HVPS to the main unit.
Insert the three screws (silver, 6 mm) into the holes circled in white.
5.
Release the upper side of the HVPS from the protrusion of the main unit, remove the HVPS, and pull
out the connectors coming out of the HVPS through the hole in the main unit.
Kmy03043EA
2)
2)
3)
4)
4)
4)
3)
3)
3)
3)
5)-1
5)-2
HVPS
LED ASSY
1.
Remove the two screws (silver, self-tapping, 8 mm) that secure the DUCT SIDE L to the main unit.
2.
Remove the DUCT SIDE L from the main unit.
3.
Remove the screw (silver, self-tapping, 10 mm) that secures the LED ASSY to the main unit.
4.
Release the two tabs on the LED ASSY and remove the LED ASSY from the main unit.
5.
Disconnect the connector (P/J141) of the LED ASSY.
C
Kmy03041EA
3)
2)
1)
1)
4)-1
4)-1
4)-2
5)
LED ASSY
Summary of Contents for AcuLaser C2800D
Page 13: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 30: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 76: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 159: ...Confidential C H A P T E R 4 DISASSEMBLY REASSEMBLY ...
Page 381: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 389: ...Confidential C H A P T E R 6 MAINTENANCE ...