AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
209
Confidential
4.
Hold down the tabs to release the LATCH FRONTs, and remove the LATCH FRONTs from the
PLATE LATCH.
Kmy03012EB
4)-2
4)-2
4)-1
4)-1
LATCH FRONT
LATCH FRONT
PLATE LATCH
HARNESS ASSY FRONT COVER
Open and close the COVER ASSY FRONT to check if the harnesses routed through the
DUCT DRV PH are under no-load conditions.
1.
Disconnect the connector (P/J272) of the HARNESS ASSY FRONT COVER (main unit side).
2.
Release the HARNESS ASSY FRONT COVER from the DUCT DRV PH.
Make sure that the ground wire (green), HARNESS ASSY-CON F (white), and HARNESS
ASSY FRONT COVER (black), which are coming out of the COVER ASSY FRONT, are
routed as shown in figure-C.
3.
Remove the screw (silver, self-tapping, 8 mm) that secures the terminal of the HARNESS ASSY
DRAWER EARTH to the COVER ASSY FRONT.
NEXT>>
E
Kmy03089EA
Ground Wire
(Green)
1)
2)
HARNESS ASSY-CON F (White)
Gap
Gap
HARNESS ASSY FRONT
COVER (Black)
Figure-C