AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
314
Confidential
4.
Remove the LEVER RELEASE from the main unit.
Mind the correct orientation when installing the LEVER RELEASE.
Install the LEVER RELEASE in reference to the illustration.
5.
Remove the LINK L from the main unit.
6.
Remove the SPRING SUPPORT from the main unit.
7.
Remove the KIT HOLDER ASSY DAMPER L from the main unit.
When installing the KIT HOLDER ASSY DAMPER L and the KIT HOLDER ASSY
DAMPER R, be careful not to mix them up. KIT HOLDER ASSY DAMPER L is black and
KIT HOLDER ASSY DAMPER R is yellow.
Kmy03050EB
6)
7)
4)
5)
(Black)
LINK L
LEVER
RELEASE
KIT HOLDER
ASSY
DAMPER L
COVER SIDE IF
1.
Release the two tabs on the COVER SIDE IF, and remove the COVER SIDE IF.
C
Kmy03008EA
1)-1
1)-1
1)-2
COVER SIDE IF