AcuLaser C2800/C2800D/C3800/C3800D
Revision C
DISASSEMBLY/REASSEMBLY
Disassembly/Reassembly
353
Confidential
COVER PWBA DUP
1.
Release the four tabs that secure the COVER PWBA DUP to the FEEDER ASSY DUP, and remove
the COVER PWBA DUP.
A B
C D E
Kmy03225EA
1)-1
1)-1
1)-1
1)-1
1)-2
COVER PWBA DUP
ACTUATOR DUP
1.
Release the four tabs that secure the HOLDER SENSOR DUP to the FEEDER ASSY DUP, and
remove the HOLDER SENSOR DUP.
2.
Disconnect the connector (P/J4301) of the SENSOR PHOTO:DUP/JAM.
3.
Expand the left and right edges of the HOLDER SENSOR DUP, pull out the shaft of the
ACTUATOR DUP, and remove the ACTUATOR DUP together with the SPRING SENSOR DUP.
Be sure to hitch the SPRING SENSOR DUP on the ACTUATOR DUP and the HOLDER
SENSOR DUP.
4.
Remove the SPRING SENSOR DUP from the ACTUATOR DUP.
A
Kmy03222EA
1)
2)
3)
3)
4)
1)
1)
1)
FEEDER ASSY DUP