AcuLaser C2800/C2800D/C3800/C3800D
Revision C
TROUBLESHOOTING
Engine-related Trouble FIP
108
Confidential
FIP 1-29 Service Req E610 (Environment Sensor Error)
Possible parts that caused the error
Troubleshooting
SENSOR HUM
HARNESS ASSY HUM
PWBA OHP SNR
HARNESS ASSY OHP SNR
HARNESS ASSY OHP
PWBA MCU
Step
Check
Yes
No
1
Check after turning the power OFF and ON
Does the error recur even when the power is
turned off and back on again?
Go to Step [2].
End of procedure
2
Check the connection of the PWBA OHP
SNR
Check the connection state between PWBA
OHP SNR and PWBA MCU.
Are P/J2411, P/J241, and P/J24 connected
correctly?
Go to Step [3].
Reconnect
P/J2411, P/J241,
and P/J24
correctly.
3
Check the continuity of the HARNESS ASSY
OHP SNR
Is the continuity between P/J2411 <=> P/J241
normal?
Go to Step [4].
Replace the
HARNESS
ASSY OHP SNR.
4
Check the continuity of the HARNESS ASSY
OHP
Is the continuity between P/J241 <=> P/J24?
Go to Step [5].
Replace the
HARNESS
ASSY OHP.
5
Replace of the PWBA OHP SNR
Replace the PWBA OHP SNR.
Was the trouble fixed?
End of procedure Go to Step [6].
6
Replace of the PWBA MCU
Replace the PWBA MCU.
Was the trouble fixed?
End of procedure Go to Step [7].
7
Check the connection of the SENSOR HUM
Check the connection state between SENSOR
HUM and PWBA MCU.
Are P/J261 and P/J26 connected correctly?
Go to Step [8].
Reconnect P/J261
and P/J26
correctly.
Step
Check
Yes
No
8
Check the continuity of the HARNESS ASSY
HUM
Is the continuity between P/J261 <=> P/J26
normal?
Go to Step [9].
Replace the
HARNESS
ASSY HUM.
9
Check the power voltage supply to SENSOR
HUM.
Measure the voltage between PWBA MCU
ground <=> P/J26-4PIN.
Is the power voltage (approx. +5 V) output?
Replace the
SENSOR HUM.
Replace the
PWBA MCU.
Summary of Contents for AcuLaser C2800D
Page 13: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 30: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 76: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 159: ...Confidential C H A P T E R 4 DISASSEMBLY REASSEMBLY ...
Page 381: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 389: ...Confidential C H A P T E R 6 MAINTENANCE ...