22
EN
Pic. 6
Control panel rear side
RJ10 jack (4x)
Power adaport jack
(by cable length > 25 m)
1/2
3/4
5/6
7/8
cabin addresses 1-8
mass storage connector type A
(for updates)
reset button
SD card reader
RJ14
RJ10
Ferrite ring with cable loop
Ferrite ring holder
!
pull the connection cable as a loop
twice through the ring
Ferrite ring is obligatory for
EMV compliance!
Display panel connection
Connect the cables always starting with the
port #1/2.
Every connection cable must be fitted with a
special ferrite ring. See pic. 6.
Take the ferrite ring off the holder (pic. 6)
and pull the connection cable twice as a loop
through the ring. Fit the ring back on the hold
and connect the cable to the corresponding
jack.
For each incoming connection cable an own
ferrite ring must be used (included with every
extension module). Thus up to 4 ferrite rings
may need to be mounted.
By connection of several cabins to one control
panel please refer to the chapter “multi-cabin
connection” for additional details.
Do not operate the display panel without the
properly mounted ferrite ring(s).
ATTENTION! Maximum connection line length for the display panel is 50 m. By cable length
over 25 m a special power adaptor (optional equipment, item 946671) is required.
The smaller RJ10 plug of the connection cable should be directed to the display panel.