60
Installation and Operating Instructions - EOS Herkules XL S120
Maintenance
EN
12
Switch on the fuses for the heater to establish a connection between
them and the mains supply.
6.5 Replacing the tubular heating elements
You can replace individual tubular heating elements or the entire heating
coil. There are two heating coils installed on the rear side of the sauna
heater. The steps for dismantling both heating coils are identical.
If the heater is too close to the wall, it may be necessary to move it so that
you can access the rear side. To move the heater manually, you must
remove the stones and the side panels.
NOTICE
Damage due to incorrect lifting of the heater
Material damage can occur if the heater is lifted from the side pan-
els. The side panels cannot bear the weight of the heater.
Remove the side panels before the heater is lifted manually.
Four people should always lift the heater.
The following steps must be complete:
Remove the stones. (See 6.2 Sauna stones,
Opening the terminal box for the heating coil,
Necessary steps:
Replacing the tubular heating elements,
Ha tools:
Tubular heating element and/or heating coil
Screwdriver
Hex key SW 5
Ring or socket spanner SW 22