EOS Herkules XL S120 - Installation and Operating Instructions
59
Maintenance
5
Allow the water to drain from the vaporiser:
a)
Lift the small cover panel on the front of the heater and then remove
it.
b)
Place the container in front of the drainage nozzle. Place a small piece
of hose on the drainage nozzle, if needed.
c)
Open the ball valve and allow the water to drain into the container
completely.
d)
Close the ball valve.
6
Moisten a cloth with alcohol or methylated spirit.
7
Thoroughly wipe down the inner walls of the vaporiser with the cloth.
Ensure that all residue from the walls is removed.
Even small amounts of essence residue on the vaporiser wall can
change the natural composition of the water, which can cause the
water to boil over with foam.
8
Mount the middle panel.
a)
Attach the base mount bracket.
b)
Screw the 4 screws in the base mount bracket.
c)
Put the middle panel in place.
d)
Screw in the 2 screws on the rear side.
9
Attach the small cover panel on the front of the heater.
10
Place the base mount and holder in position.
11
Open the shut-off valve to the potable water connection.