This chapter describes how to install the sauna heater. The sauna heater is
not designed to be installed or set up in an alcove or under a bench or
sloping roof unless this sauna heater is specifically designed and approved
for this type of installation. Prior to installing the unit, air inlets and outlets
must be attached to the cabin. It may be necessary to mount additional
fans in the inlets/outlets. All protective films must be removed.
3.1 Specifications for the cabin
The cabin must be planned and installed according to specifications before
the sauna heater is installed.
The floor on which the sauna heater stands must be level. In general, it
should be noted that the sauna heater must not be set on a floor made of
highly flammable material (laminate, flooring made of plastic material,
etc.). Ceramic tiles are recommended as a flooring option.
Electrical lines
All electrical installations laid inside the cabin must be suitable for silicone
cables and a temperature of at least 170°C. All lines must be routed in such
a way that they are well-protected, e.g. in a cable duct.
If single-core lines are used as connecting cables, they must be protected
by a flexible metal hose that is connected to the protective conductor.
The minimum cross-section of the connecting cable and the suitable cabin
size in relation to the connecting cable in kW can be found here:
2.4 Technical data,
Clearances
The measurements for clearances can be found in the figures in the chap-
ter 3.1.1 Installation site,
19.
When installing the sauna heater, ensure that the vertical clearance
between the top edge of the sauna heater and the cabin ceiling is
observed. The distance between the lower edge of the sauna heater and
the floor can be found in the dimension drawing. The clearance for stand-
ing heaters is determined by the base or the supporting feet.
The amount of clearance required between the sauna heater and the
heater's protective grill or the sauna bench and other flammable material
can be found in the dimension specifications for the respective sauna
heater. The height of the heater's protective grill must equal approximately
the height of the front of the sauna heater.