48
Installation and Operating Instructions - EOS Herkules XL S120
Connections
EN
EOS Herkules XL S120 Vapor: checking the water installation for
leaks
1
Open the shut-off valve for the water supply.
2
Inspect all sections of the water installation.
The connections must be free of water leaks.
EOS Herkules XL S120 Vapor: setting the water level
1
Set the water level by raising or lowering the float gauge.
The water level should be 72 cm high when measuring from the floor
up.
Water level in cm
2
Attach the cover for the water level control.
Attaching the warning plate
1
Attach the warning plate so it is in close proximity to the sauna heater
and clearly visible at eye level.
2
Attach the plate with the 2 supplied screws (2.9 mm x 9.5 mm).
~
72