Installing the air inlet in the cabin floor
Air outlet
The air outlet must meet the following criteria:
Location: Across from the sauna heater
Height: 30–50 cm above the cabin floor
3.1.3 Connection cable
The sauna heater must be connected to the relay box by means of one or
two connection cables, depending on the heater output. Install the cables
in such a way that they are protected from damage. To do this, route empty
pipes from the installation site of the sauna heater to the relay boxes.
Outside of the cabin, the cables must be routed under a suitable protective
cover (e.g. in a cable duct or empty conduits).
See the connection diagram:
Connection diagrams for sauna systems
If there are no empty pipes in your cabin, drill a hole in the cabin wall
directly next to the sauna heater where the cable emerges from the sauna
heater, and guide the cable through this hole outward to the control unit.
The hole must be large enough to accommodate the cable. The cable and
all other connection cables (supply line to mains and cabin lighting) on the
external side of the cabin must be protected from damage. To do this, use
installation pipes or attach wood skirting strips.