EOS Herkules XL S120 - Installation and Operating Instructions
15
Identification
The door supervision device can be purchased together with the heater
monitor.
2.4 Technical data
The sauna heater is operated by a sauna control unit.
All line cross-section specifications are the minimum cross-sections of a
copper line.
EOS Herkules XL S120 – electrical connection data
EOS Herkules XL S120 – sauna heater data
Heater monitor/door supervision device combination
(optional)
Item no.
EOSafe L & D with 25 mm reflector
94.7153
EOSafe L & D with 50 mm reflector
94.7152
Heater
output
Electrical
connec-
tion
Fuse protection
Connections
Control
unit
LSG
Mains –
control unit
Mains –
LSG
Control
unit – heater
LSG – heater
Control
unit – LSG
18 kW
400 V
3N AC
50 HZ
3 x 16 A
3 x 16 A
5 x 2.5 mm² 5 x 2.5 mm²
5 x 1.5 mm²
5 x 1.5 mm²
4 x 1.5 mm²
24 kW
3 x 16 A
3 x 35 A
5 x 2.5 mm²
5 x 6 mm²
5 x 1.5 mm²
5 x 4 mm²
30 kW
1 x 16 A
3 x 63 A
3 x 1.5 mm² 5 x 16 mm²
–
2 x (5 x 4 mm²)
Heater
output
Unit dimen-
sions
HxWxD in
cm
For sauna
cabin size
Minimum
size of air
inlet and
outlet
Weight
without
rocks
Stone filling Relay boxes
Suitable con-
trol unit
18 kW
85 x 96 x 53
24–35 m³
50 x 6 cm
approx. 8
5 kg
2 x 60 kg
EMOTEC L09 R
EmoStyle
Emotec
EmoTouch ECO
N
24 kW
35–45 m³
50 x 8 cm
LSG 18
30 kW
45–65 m³
50 x 10 cm
LSG 36