NT INTEGRATED FLOW CONTROLLER WITH DEVICENET COMMUNICATION
27
Entegris, Inc. | User Guide
IDENTITY OBJECT (01
HEX
)
—
Class
Attributes 1.0 – Class Attributes – Identity Object
ATT. ID
REQUIRED
SUPPORTED
ACCESS
RULE
NAME
DATA
TYPE
ATTRIBUTE
DESCRIPTION
VALUES
1
Optional
Yes
Get
Revision
UINT
Object revision
= 01
Services 1.0 – Class Services – Identity Object
CODE
REQUIRED
SUPPORTED
NAME
PARAMETERS DESCRIPTION
PARAMETER
VALUES
0E
hex
Required
Yes
Get_Attribute_
Single
Attribute ID
(USINT)
Retrieves an
attribute value
1–255
Instance 1
Attributes 1.1 – Instance Attributes – Identity Object 1
ATT.
ID
REQUIRED
SUPPORTED
ACCESS
RULE
NV
NAME
DATA
TYPE
ATTRIBUTE
DESCRIPTION
VALUES
1
Required
Yes
Get
NVC Vendor
ID
UINT
ODVA
assigned
identification
of vendor
864 = NT
International
2
Required
Yes
Get
NVC Device
type
UINT
Indication of
general type
of product
0000
3
Required
Yes
Get
NVF
Product
code
UINT
Indication of
a particular
product of
an individual
vendor
0001
4
Required
Yes
Get
NVC
Revision STRUCT
of:
Major
revision
USINT
01
Minor
revision
USINT
01