NT INTEGRATED FLOW CONTROLLER WITH DEVICENET COMMUNICATION
31
Entegris, Inc. | User Guide
Attributes 3.1 – Instance Attributes – DeviceNet Object 1 (continued)
ATT.
ID
REQUIRED
SUPPORTED
ACCESS
RULE
NV
NAME
DATA
TYPE
ATTRIBUTE
DESCRIPTION
VALUES
7
Required
Yes
Get
V
BAUD
Swt Chg
BOOL
Changed
since last
reset (media
access)
0 = No change
1 = Changed
8
Required
Yes
Get
V
MACID
Swt Chg
USINT
Actual switch
value
0–99
9
Required
Yes
Get
V
BAUD
Swt Chg
USINT
Actual switch
value
0–9
* If the corresponding configuration switch is higher than the attribute’s limit,
the attribute has SET access.
Services 3.1 – Instances Services – DeviceNet Object 1
CODE
REQUIRED
SUPPORTED
NAME
PARAMETERS DESCRIPTION
PARAMETER
VALUES
0E
hex
Required
Yes
Get_Attribute_
Single
Attribute ID
(USINT)
Retrieves an
attribute value
1–255
10
hex
Required
Yes
Set_Attribute_
Single
Attribute
ID (USINT);
Value
Sets an attribute
value
Attribute
ID = 1–255
Value =
attribute
specific
4B
hex
Required
Yes
Allocate_
Master/Slave_
Connection_Set
Allocation
choice;
Master
Initializes
predefined
master/slave
connection set
0 × 01 =
Explicit
0 × 02 = Poll
0 × 03 = Both
4C
hex
Required
Yes
Release_
Group_2_
Identifier_Set
Allocation
choice
Releases
predefined
master/slave
connection set
0 × 01=
Explicit
0 × 02 = Poll
0 × 03 = Both