NT INTEGRATED FLOW CONTROLLER WITH DEVICENET COMMUNICATION
60
User Guide | Entegris, Inc.
Attributes 64.1 – Instance Attributes – S-Sensor Calibration Object 1
(continued)
ATT.
ID
REQUIRED
SUPPORTED
ACCESS
RULE
NV
NAME
DATA
TYPE
ATTRIBUTE
DESCRIPTION
VALUES
4
Required
Yes
Get
NVC Valid
sensor
instance
UINT
S-Analog sensor
object instance
ID for which this
object instance
is valid
= 01
5
Optional
Yes
Set
NV
Calibra-
tion
name
SHORT
STRING
ASCII text, max
50 characters,
User accessible
string represen-
tation used to
identify the
calibration or
application
[default] =
Null
6
Optional
Yes
Get
NVF Full
scale
STRUCT of: Full scale of the
device using this
object instance
[default] =
0, 0
REAL
Amount
ENGUNITS
Units
Services 64.1 – Instance Services – S-Sensor Calibration Object 1
CODE
REQUIRED
SUPPORTED
NAME
PARAMETERS DESCRIPTION
PARAMETER
VALUES
0E
hex
Required
Yes
Get_Attribute_
Single
Attribute ID
(USINT)
Retrieves an
attribute value
1 – 255
10
hex
Required
Yes
Set_Attribute_
Single
Attribute
ID (USINT);
Value
Sets an attribute
value
Attribute ID =
1 – 255
Value =
attribute
specific