NT INTEGRATED FLOW CONTROLLER WITH DEVICENET COMMUNICATION
38
User Guide | Entegris, Inc.
Instance 2 – Polled
Attributes 5.2 – Instance Attributes – Connection Object 2
ATT.
ID
REQUIRED
SUPPORTED
ACCESS
RULE
NAME
DATA
TYPE
ATTRIBUTE
DESCRIPTION
VALUES
1
Required
Yes
Get
State
USINT
Object state
See Instance 1
2
Required
Yes
Get
Instance
type
USINT
= Poll
= 01
3
Required
Yes
Get
Trans Class/
Trig
USINT
= Server Class 2
= 0×82
4
Required
Yes
Get
P Conn ID
UINT
Poll Resp. CAN ID = 01111xxxxxx;
x = MACID
5
Required
Yes
Get
C Conn ID UINT
Poll Req. CAN ID = 10xxxxxx101;
x = MACID
6
Required
Yes
Get
Initial
Comm
charac-
teristics
BYTE
Group IDs
= 0×01
7
Required
Yes
Get
P Conn
size
UINT
Produced data
size
= Size of selected
input assembly
data
8
Required
Yes
Get
C Conn
size
UINT
Consumed data
size
= Size of selected
output assembly
data
9
Required
Yes
Set
EPR
UINT
Expected
packet rate in
milliseconds
0 = Default
12
Required
Yes
Set
WTO action USINT
Watch dog
timeout action
00 = Time out
(default)
01 = Auto delete
13
Required
Yes
Get
P Conn
Path length
UINT
Path length
= 06
14
Required
Yes
Set
P Conn
Path
EPATH
Path from which
connection
produces
= 20 04 24 NN 30
03 (hex) where
NN = assembly
inst id
15
Required
Yes
Get
C Conn
Path length
UINT
Path length
= 06
16
Required
Yes
Set
C Conn
Path
EPATH
Path to which
connection
consumes
= 20 04 24 NN 30
03 (hex) where
NN = assembly
inst id