NT INTEGRATED FLOW CONTROLLER WITH DEVICENET COMMUNICATION
34
User Guide | Entegris, Inc.
Instances – Identifiers
4.N Assembly Object Instances
NUMBER
REQUIRED
TYPE
ELEMENTS
1
Y
Input
Flow
2
Y (default)
Input
Status and flow
3
N
Input
Status, flow, and pressure
6
N
Input
Status, flow, pressure, and valve
10
Y (default)
Output
Setpoint
11
Y
Output
Override and setpoint
Element Mapping
Assembly Object Element Mapping
DATA
COMPONENT
NAME
CLASS
INSTANCE
NUMBER
ATTRIBUTE
NAME
NUMBER
NAME
NUMBER
TYPE
Flow
S-Analog sensor
31
hex
1
Value
6
INT
Pressure
S-Analog sensor
31
hex
2
Value
6
INT
Valve
S-Analog actuator
32
hex
1
Value
6
INT
Override
S-Analog actuator
32
hex
1
Override
5
USINT
Setpoint
S-Single stage
controller
33
hex
1
Setpoint
6
INT
Status
S-Device supervisor
30
hex
1
Exception
status
12
BYTE