NT INTEGRATED FLOW CONTROLLER WITH DEVICENET COMMUNICATION
20
User Guide | Entegris, Inc.
Reference
Physical specifications
PART
CONSTRUCTION MATERIALS
Wetted parts
Body
PTFE
Diaphragms
PTFE
Sensor interface
CTFE or PFA
O-rings
Kalrez
®
6375 UP
Nonwetted parts
Polypropylene, FEP, PVDF, Viton
®
(in addition to the
materials listed above)
Connection type
Flaretek tube fitting
Enclosure
IP54
Power cable specifications
Input voltage
24 VDC ±10%
Input current
1.0 A nominal, 1.2 A peak
Electrical connection
12' length with 22 ga wire PVC-jacketed wire
DeviceNet cable specifications
Input voltage
24 VDC ±10%
Input current
150 mA nominal
Electrical connection
12' length with 22 ga wire PVC-jacketed wire
Performance specifications
Flow accuracy
±1.0% FS at 20% to 100% of flow range, ±2.5% FS at
10% to 20% of flow range.
Accuracy defined for 20 seconds average, using DI water
at 23°C (73°F).
Accuracy not specified 0% to 10% of flow range.
Pressure accuracy
±1.0% FS (full scale is 414 kPa [60 psig]) (includes the combined
effects of linearity, hysteresis, and repeatability)
Repeatability
±0.5% FS at 20% to 100% of flow range
±1.0% FS at 10% to 20% of flow range
Response time
< 3 seconds from 10-95% of full scale flow range
Process temperature
10° – 65°C (50° – 149°F)
Storage temperature
-40° – 50°C (-40° – 122°F)
Operating pressure
69 – 414 kPa (10 – 60 psig)
Over-pressure limit
690 kPa (100 psig)
NOTE: Specifications are subject to change without notice.