Specifications
Operating Voltage:
8 VDC Minimum to 14.4 VDC Maximum (Designed
to work on 12 VDC systems).
Operating Temperature:
-40
o
to 80°C (-40 to 176°F)
Storage Temperature:
-40° to 80°C (-40° to 176°F)
Environmental Sealing
: IP65
Relative Humidity:
95%RH @ 60°F (140°C)
Standby Current:
140mA @ 12VDC for standby current. 600mA Max @
12VDC when not in standby.
CAN Bus:
SAE J1939 Compliant
Enclosure:
Polycarbonate NEMA 4 (UL/cUL listed)
Analog Inputs:
6 Analog Inputs designated via program; sender/ground
digital 4-20mA, 0-5 VDC.
Digital Inputs
: 4 Digital Inputs high/low (Both and ground are
detected as active inputs. An inactive input floats at approximately 1/2
B+).
Frequency
: 1 optically isolated input for speed reference, magnetic pick-
up, (2VAC-50VAC RMS, 30-10kHz).
Fuel Sender Input
: 33 Ohm full, 240 Ohm empty
Analog Output
: 4-20mA or .4 to 4.2VDC (used for .4 – 4.2V throttling)
Digital Outputs
: 6 Digital Outputs; 3 FET B+ (rated at 1A), 3 Open
Collector sink-to-ground 100 mA (one of these is used to pilot a relay)
User Interface
: 8-button keypad, Graphical display, back-lit.
Communications
: RS485, RS232, CAN J1939, CAN 2.0B ports
Shipping Weight
: 7 lb. (3.2 kg)
Shipping Dimensions
: 12x12x10 (304.8x304.8x254 mm)
Real-time Clock
: 24hr Format
Summary of Contents for Murphy EMS PRO LITE
Page 4: ......
Page 8: ...NOTES ...
Page 22: ...Section 40 00 02 0787 2015 03 23 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 60: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 61: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 62: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 63: ......