Technical data
Proline Promag W 500 PROFINET
234
Hauser
2.5
[%]
2.0
1.5
1.0
0.5
0
0.2 %
0.5 %
0
1
2
4
6
8
10 [m/s]
v
5
10
15
20
25
30
32 [ft/s]
0
A0028974
47
Maximum measured error in % o.r.
2.5
[%]
2.0
1.5
1.0
0.5
0
0.2 %
0.5 %
0
[m/s]
v
[ft/s]
v
0.2
v
0.5
0
v
max
A0017051
48
Flat Spec in % o.r.
For Flat Spec 0.5 %, the measured error is constant as of a flow velocity of v
0.5
.
Flat Spec flow values0.5 %
Nominal diameter
v
0.5
v
max
[mm]
[in]
[m/s]
[ft/s]
[m/s]
[ft/s]
25 to 600
1 to 24
0.5
1.64
10
32
50 to 300
2 to 12
0.25
0.82
5
16
1)
Order code for "Design", option C "Fixed flange, without inlet/outlet runs"
For Flat Spec 0.2 %, the measured error is constant as of a flow velocity of v
0.2
.
Flat Spec flow values0.2 %
Nominal diameter
v
0.2
v
max
[mm]
[in]
[m/s]
[ft/s]
[m/s]
[ft/s]
25 to 600
1 to 24
1.5
4.92
10
32
50 to 300
2 to 12
0.6
1.97
4
13
1)
Order code for "Design", option C "Fixed flange, without inlet/outlet runs"