Proline Promag W 500 PROFINET
Electrical connection
Hauser
45
Cross-section
Cable lengths for use in
Non-hazardous area,
Hazardous area: Zone 2;
Class I, Division 2
Hazardous area: Zone 1;
Class I, Division 1
1.50 mm
2
(AWG 15)
300 m (1
000 ft)
180 m (600 ft)
2.50 mm
2
(AWG 13)
300 m (1
000 ft)
300 m (1
000 ft)
Optionally available connecting cable
Design
2 × 2 × 0.34 mm
2
(AWG 22) PVC cable
with common shield (2 pairs,
uninsulated stranded CU wires; pair-stranded)
Flame resistance
According to DIN EN 60332-1-2
Oil-resistance
According to DIN EN 60811-2-1
Shielding
Tin-plated copper-braid, optical cover ≥ 85 %
Operating temperature
When mounted in a fixed position: –50 to +105 °C (–58 to +221 °F); when cable
can move freely: –25 to +105 °C (–13 to +221 °F)
Available cable length
Fixed: 20 m (65 ft); variable: up to maximum 50 m (165 ft)
1)
UV radiation can impair the cable outer sheath. Protect the cable from direct sunshine where possible.
B: Connecting cable between sensor and transmitter: Proline 500
Signal cable
Design
3 × 0.38 mm
2
(20 AWG) with common, braided copper shield (⌀
9.5 mm (0.37 in)) and individual shielded cores
If empty pipe detection
(EPD) is used
4 × 0.38 mm
2
(20 AWG) with common, braided copper shield (⌀
9.5 mm (0.37 in)) and individual shielded cores
Conductor resistance
≤50 Ω/km (0.015 Ω/ft)
Capacitance: core/shield
≤420 pF/m (128 pF/ft)
Cable length (max.)
Depends on the medium conductivity, max. 200 m (656 ft)
Cable lengths (available
for order)
5 m (15 ft), 10 m (32 ft), 20 m (65 ft) or variable length up to max.
200 m (656 ft)
Operating temperature
–20 to +80 °C (–68 to +176 °F)
Coil current cable
Design
3 × 0.75 mm
2
(18 AWG) with common, braided copper shield (⌀
9 mm (0.35 in)) and individual shielded cores
Conductor resistance
≤37 Ω/km (0.011 Ω/ft)
Capacitance: core/core,
shield grounded
≤120 pF/m (37 pF/ft)
Cable length (max.)
Depends on the medium conductivity, max. 200 m (656 ft)
Cable lengths (available
for order)
5 m (15 ft), 10 m (32 ft), 20 m (65 ft) or variable length up to max.
200 m (656 ft)
Operating temperature
–20 to +80 °C (–68 to +176 °F)
Test voltage for cable
insulation
≤ AC 1433 V rms 50/60 Hz or ≥ DC 2026 V
Summary of Contents for Proline Promag W 500
Page 262: ...www addresses endress com...