26534-1-0610
Page 8
Figure 6
The gas pipeline can be brought in through the right or left side of
the appliance. Consult the current National Fuel Gas Code, ANSI
Z223.1 CAN/CGA-B149 (.1 or .2) installation code.
Installing a New Main Gas Cock
Each appliance should have its own manual gas cock.
A manual main gas cock should be located in the vicinity of
the unit. Where none exists, or where its size or location is not
DGHTXDWH FRQWDFW \RXU ORFDO DXWKRUL]HG LQVWDOOHU IRU LQVWDOODWLRQ
or relocation.
Compounds used on threaded joints of gas piping shall be resistant
WRWKHDFWLRQRIOLTXH¿HGSHWUROHXPJDVHV7KHJDVOLQHVPXVWEH
checked for leaks by the installer. This should be done with a soap
solution watching for bubbles on all exposed connections, and if
unexposed, a pressure test should be made.
1HYHUXVHDQH[SRVHGÀDPHWRFKHFNIRUOHDNV$SSOLDQFHPXVW
be disconnected from piping at inlet of control valve and pipe
capped or plugged for pressure test. Never pressure test with
appliance connected; control valve will sustain damage!
NOTE:
7KHPLOOLYROWJDVFRQWUROVDUHHTXLSSHGZLWKDFDSWXUHG
screw type pressure test point, therefore it is not necessary to provide
a 1/8" test point up stream of the control.
2QGLUHFWLJQLWLRQYDOYHVKH[SOXJVPD\EHUHSODFHGZLWKKRVH¿WWLQJV
IRUSUHVVXUHFKHFNVWKHQUHLQVWDOOHGEHIRUHRSHUDWLQJ¿UHSODFH
:KHQXVLQJFRSSHURUÀH[FRQQHFWRUXVHRQO\DSSURYHG¿WWLQJV
The appliance and it’s individual shut off valve must be disconnected
from supply piping system during any pressure testing of that system
at test pressures in excess of 1/2 psig (3.5kPa).
The appliance must be isolated from the gas supply piping system
by closing its individual manual shut off valve during any pressure
WHVWLQJRIWKHJDVVXSSO\SLSLQJV\VWHPDWWHVWSUHVVXUHVHTXDOWRRU
less than 1/2 psig (3.5kPa).
Attention!
If one of the procedures results in pressures in excess
RISVLJZFN3DRQWKH¿UHSODFHJDVYDOYHLWZLOO
result in a hazardous condition.
Gas Supply Pressure (inches w.c.)
Minimum
Normal
Maximum
Natural Gas
4.5"
7.0"
14.0"
LP (Propane)
10.8"
11.0"
14.0"
Manifold Pressure (inches w.c.)
Normal (HI)
Natural Gas
3.5"
LP (Propane)
10.0"
Recommended Gas Pipe Diameter
Pipe Length
(Feet)
Schedule 40 Pipe
Inside Diameter
Tubing, Type L
Outside Diameter
Nat.
L.P.
Nat.
L.P.
0-10
1/2"
12.7mm
3/8"
9.5mm
1/2"
12.7mm
3/8"
9.5mm
11-40
1/2"
12.7mm
1/2"
12.7mm
5/8"
15.9mm
1/2"
12.7mm
41-100
1/2"
12.7mm
1/2"
12.7mm
3/4"
19mm
1/2"
12.7mm
101-150
3/4"
19mm
1/2"
12.7mm
7/8"
22.2mm
3/4"
1.9 mm
Note:
1HYHUXVHSODVWLFSLSH&KHFNWRFRQ¿UPZKHWKHU\RXUORFDO
codes allow copper tubing or galvanized.
Note:
Since some municipalities have additional local codes, it is
always best to consult your local authority and installation code.
The use of the following gas connectors is recommended:
— ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing
and Fittings.
— ANS Z21.45 Assembled Flexible Appliance Connectors of
Other Than All-Metal Construction
The above connectors may be used if acceptable by the authority
KDYLQJMXULVGLFWLRQ7KHVWDWHRI0DVVDFKXVHWWVUHTXLUHVWKDWDÀH[LEOH
appliance connector cannot exceed three feet in length.
GAS SUPPLY