The OWNER should carefully read and follow these operating
instructions at all times. Lower the door assembly to view the gas
FRQWUROVIRUWKH¿UHSODFH
Initial Lighting
Upon completing the gas line or turning the gas valve on after it
has been in the “OFF” position, a small amount of air will be in the
OLQHV:KHQ¿UVWOLJKWLQJWKH¿UHSODFHLWZLOOWDNHDIHZPLQXWHV
for the lines to purge themselves of this air. Once the purging is
FRPSOHWHWKH¿UHSODFHZLOOOLJKWDQGRSHUDWHVDWLVIDFWRULO\
6XEVHTXHQWOLJKWLQJVRIWKHDSSOLDQFHZLOOQRWUHTXLUHVXFKSXUJLQJ
if the gas valve is not turned to “OFF.”
Pilot Flame (Figure 22)
The thermopile (standing pilot) tips should be covered with
ÀDPH
Figure 22
750 Millivolt System
The standing pilot (750 millivolt system) is a continuous burning
pilot. The pilot remains ON even when the main burner is OFF.
When you ignite the pilot, the thermopile produces millivolts
(electrical current) which energizes the magnet in the gas valve.
After 30 seconds to 1 minute time period you can release the gas
FRQWURONQREDQGWKHSLORWZLOOVWD\21$OORZ\RXUSLORWÀDPHWR
operate an additional one (1) to two (2) minutes before you turn the
gas control knob from the PILOT position to the ON position. This
time period allows the millivolts (electrical current) to build-up to
DVXI¿FLHQWOHYHODOORZLQJWKHJDVFRQWUROWRRSHUDWHSURSHUO\
1. Follow the SAFETY and LIGHTING INSTRUCTIONS for
standing pilot controls found in this manual and on labels found
in control compartment behind the door assembly.
CAUTION: During the initial purging and subsequent lightings,
never allow the gas valve control knob to remain depressed in
WKH³SLORW´SRVLWLRQZLWKRXWSXVKLQJWKHSLH]RLJQLWRUEXWWRQ
at least once every second.
2. During the operating season, leave the control valve knob in
WKH³21´SRVLWLRQ7KLVZLOODOORZWKHSLORWÀDPHWRUHPDLQOLW
7XUQWKHEXUQHUÀDPHRQRURIIZLWKWKH¿UHSODFHZDOOVZLWFK
or remote controls.
3. When the operating season is over, turn the wall switch or
remote to “OFF” and the control valve to “OFF”. The system,
including the pilot light, will be shut down.
Figure 21
OPERATING INSTRUCTIONS