26534-1-0610
Page 25
With proper installation and maintenance, your new Gas Fireplace will provide years of trouble-free service. If you do experience a
SUREOHPUHIHUWRWKHWURXEOHVKRRWLQJJXLGHEHORZ7KLVJXLGHZLOODVVLVWDTXDOL¿HGVHUYLFHSHUVRQLQWKHGLDJQRVLVRISUREOHPVDQG
the corrective action to be taken. Refer to page 24 for initial startup and GAS Line purge instructions.
SYMPTOM
CHECK
ACTION
No spark when system is turned to “ON”
and reset cycle* has been completed.
Check for 120V between black “hot” line
at control module and “white” return at
module.
If 120V not present, check fuse or circuit
breaker or repair wiring leading to
¿UHSODFH
Spark for six (6) seconds at ignitor, but no
ignition of burner.
a. Check that gas is turned on and system
purged.
Turn gas on and/or purge system.
b. Check that tips of ignitor are directly
above ports on main burner. Spark is
between electrodes and not from one
electrode to burner.
Position electrodes so tips are directly
above burner port ports and about ¼" to
3
/
8
" above burner.
c. Check for 120V at each coil on the gas
valve and listen for click, indicating gas
valve is opening.
If 120V present, but gas valve does not
click, replace gas valve.
Spark for six (6) seconds, main burner
lights, but goes out when spark stops.
Check for clean ground path between
electrode bracket and fireplace chassis.
Check wiring to wiring diagram label.
Check for broken electrode on high-tension
lead attachment to module.
Clean, position according to wiring diagram,
and repair defective electric connections. If
all electrical connections are clean and
correct, replace module.
Main burner lights normally and then goes
out.
a. Check ignitor to burner gap.
Igniter should be located 1/4" to 3/8" above
burner area.
b. Check high-tension lead and connector
for shorts.
Replace spark electrode assembly.
c. Refer to installation instructions
troubleshooting guide for issues such
as venting.
5HSDLUDVUHTXLUHG
The conversion shall be carried out in accordance with the
requirements of the provincial authorities having jurisdiction
DQGLQDFFRUGDQFHZLWKWKHUHTXLUHPHQWVRIWKH&6$%
installation code (Canada) and with the requirements of the
1DWLRQDO)XHO*DV&RGH=1)3$8QLWHG6WDWHV
WARNING: This conversion kit shall be installed by a
TXDOL¿HGVHUYLFHDJHQF\LQDFFRUGDQFHZLWKWKHPDQXIDFWXUHUV
instructions and all applicable codes and requirements
of the authority having jurisdiction. If the information in
WKLV LQVWUXFWLRQ LV QRW IROORZHG H[DFWO\ D ¿UH H[SORVLRQ RU
production of carbon monoxide may result causing property
GDPDJHSHUVRQDOLQMXU\RUORVVRIOLIH7KHTXDOL¿HGVHUYLFH
agency is responsible for the proper installation of this kit.
The installation is not proper and complete until the operation
RI WKH FRQYHUWHG DSSOLDQFH LV FKHFNHG DV VSHFL¿HG LQ WKH
manufacturer's instructions supplied with the kit.
Installer notice:
8VLQJDQLQNSHQ¿OORXWWKHUHTXLUHGLQIRUPDWLRQ
on the conversion label. Remove the backing from label and
VWLFNODEHOLQDYLVLEOHSRVLWLRQRQERWWRPRI¿UHSODFHFORVHWR
gas valve.
Installer notice:
These instructions must be left with the
appliance.
,QVWUXFWLRQVIRUFRQYHUWLQJ\RXUGLUHFWLJQLWLRQ¿UHSODFHIURP
natural gas to propane/LP gas.
$OOGLUHFWLJQLWLRQ¿UHSODFHVDUHVKLSSHGIURPWKHIDFWRU\HTXLSSHG
WRRSHUDWHRQQDWXUDOJDV7RFRQYHUWWKHGLUHFWLJQLWLRQ¿UHSODFH
to operate on propane/LP gas, follow the instructions on Page
26. Please see the appropriate parts list for your model for parts
LQFOXGHGZLWKWKHGLUHFWLJQLWLRQ¿UHSODFH
Check the items in the kit with the parts list. Notify the supplier of
any items that are missing before installing the conversion kit.
DIRECT IGNITION TROUBLESHOOTING
DIRECT IGNITION PROPANE/LP GAS CONVERSION