ELECTRICAL CONNECTIONS
CAUTION
All wiring should be done by a qualified electrician and
shall be in compliance with all local, city and state building
codes. Before making the electrical connection, make sure
that the main power supply is disconnected. The fireplace,
when installed, must be electrically grounded in accordance
with local codes, or in the absence of local codes, with the
National Electrical Code ANSI/NFPA 70 (Latest Edition).
A factory installed junction box is located on the lower right
side of the fireplace. Wiring must be fed to the junction box and
attached to the receptacle that is provided. Leave approximately
6in of wire in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to
opposite side of receptacle. The ground wire should be attached
to the green (ground) screw.
See Figure 18.
Figure 18
Install the receptacle into the junction box. Attach cover plate.
After the wiring is completed to the junction box and the receptacle,
and power module cord is plugged in, re-install the junction box.
See Figure 19.
Figure 19