background image

LT----Iss - (--/--) 

 
 
 
 
 

Rosmore 

Owner's Book

 

 
 

INCLUDES USER, INSTALLATION & MAINTENANCE 

INSTRUCTIONS 

 
 
 
 

Please read these instructions carefully before you start using the 

appliance 

 
 

Keep this booklet handy for future reference 

 
 

This appliance is 

for use in GREAT BRITAIN or IRELAND only 

 

 

 
 

Summary of Contents for Rosmore

Page 1: ...CLUDES USER INSTALLATION MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is for use in GREAT BRITAIN or IRELAND only ...

Page 2: ...e in the Wall installations 12 Clearance to Shelf 13 Clearance to Side of Fire 13 Ventilation 13 SECTION NINE To Install the Appliance 13 Examine Flue Chimney 13 Connecting to the Gas Supply 13 Gas Concealed Connection 14 Gas Connection From the Front 14 Fixing Fire into Opening 14 Optional Cable Fixing System 14 Checking Gas Soundness 15 Fuel Bed Layout 15 Checking Operation of Fire 15 Checking P...

Page 3: ...ontact with skin or eyes Use disposable gloves facemasks and eye protection After handling wash hands and other exposed parts If a vacuum is used for cleaning the fuel bed or cleaning after servicing installation it is recommended that it be of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a minimum these materials should be securely wrapped in polythe...

Page 4: ... checked prior to contacting a service engineer SECTION TWO Operation The pilot can be left on or the pilot can be extinguished and relit each time the fire is used The appliance Control Knob is positioned behind the fret The full lighting procedure is as follows a Push knob in as far as possible on gas control b Turn knob anti clockwise until a click is heard The knob will stop at the position ma...

Page 5: ...d CARE SHOULD BE TAKEN TO AVOID CONTACT WITH THE REFRACTORY LINING THIS IS A DELICATE SURFACE AND SHOULD NOT BE WIPED OR RUBBED FUEL BED LAYOUT COAL OPTION Coal set provided consists of 6 off shape A coals 12 off shape B coals 1 off Left hand front coal matrix 1 off Right hand front coal matrix 1 off Base coal matrix IMPORTANT Keep the coals in separate groups for laying on the fire bed Place the ...

Page 6: ...d Layout Cont Place the first row of 3 x A and 3 x B overlay loose coals as shown between the front coals and base matrix Make sure that they are stable and DO NOT let them fall down in the gaps between the peaks on the matrix Add 2 x A loose coal as shown Add 4 x B coals as shown ...

Page 7: ...Fuel Bed Cleaning and Layout Cont Add 2 x type B coals and 1 x type A as shown Add the final 3 x B coals as shown The layout is now finished Note Dye is available for touching up coal and liner board surfaces where the black colouring may have rubbed off in use ...

Page 8: ... ventilation is provided it should be checked periodically to ensure freedom from obstruction Ventilation in the Republic of Ireland Must be permanent ventilation and must comply with the rules in force and should be checked periodically to ensure freedom from obstruction General Appliance Care Any debris from the chimney or flue should be removed from the fuel bed The fire should be allowed to co...

Page 9: ...gs SECTION SIX Regulations and Warnings THIS APPLIANCE MUST ONLY BE INSTALLED IN GB OR IRELAND Only to be used in sufficiently ventilated room Read instructions carefully before installation and use The appliance must be installed by a competent person i e Gas Safe Registered Installer in accordance with the current Gas Safety Installation and Use Regulations 1998 as amended Failure to do so could...

Page 10: ...ent Office SECTION SEVEN Siting the Appliance The fire can be installed in the following flues and locations CLASS ONE A conventional brick or stone chimney as used for a solid fuel appliance with a typical effective cross sectional dimension of 225 x 225 mm 9 x 9 ins or a lined flue with a minimum diameter of 125 mm 5 ins This includes pre cast flue systems Note The restrictor plate fitted to the...

Page 11: ... above flues The flue must only service a single appliance and not have any branches or traps which may impede the natural draught If a terminal is fitted it must be suitable for the purpose SECTION EIGHT Fireplace Requirements A flat face of 600 mm high x 500 mm wide must be provided around the fireplace opening for the fixing of the appliance to ensure that a good seal is formed The base of the ...

Page 12: ...e or is an integral part of the fascia of the appliance Consideration should be given to the location of the appliance ensuring it is very visible and it should be positioned at a height were it can clearly be seen on approach Frets and Fascias used for HOLE in the WALL must be compliant with Paragon Fires CE approval these are listed at the end of this page Where the fire is fitted as a Hole in t...

Page 13: ...o close to the appliance VENTILATION In the United Kingdom no special ventilation bricks or vents are required into the room containing the appliance provided normal adventitious room ventilation exists The installer must satisfy this point by carrying out a mandatory spillage test In the Republic of Ireland permanent ventilation must comply with the rules in force SECTION NINE To Install the Appl...

Page 14: ...the required position A suitable isolating cock must always be fitted in the supply feed to the fire to facilitate servicing A suitable restrictor elbow is supplied with the fire FIXING FIRE INTO OPENING Remove the paper backing from the length of foam seal and stick it around the rear flange of fire If a spacer is going to be used stick the second length supplied with the spacer kit around the re...

Page 15: ...essure gauge Turn on gas the appliance Purge the air from the appliance by rotating the control to the ignition position push in to allow the air in the pipework to be purged and the piezo to ignite the pilot Check that the electrode is sparking at the gap between the thermocouple tip and the electrode continue until pilot ignition is established Depress the control knob slightly and rotate anti c...

Page 16: ...ng effect of heating the fuel bed and other refractory components will cause an initial odour This is due to the starch used in the manufacturing process and is non toxic Any debris should be cleaned from the appliance A vacuum cleaner can be used but only after all the loose components have been removed The appliance should be serviced annually by a competent person in accordance with these instr...

Page 17: ...uel bed components 4 Remove plastic knob from gas control tap 5 Disconnect gas supply from inlet elbow of appliance right of gas control tap 6 Undo and remove four screws from bezel plate at front of appliance 7 Undo locknut on front of gas valve and lift away bezel plate 8 Undo and remove two screws securing the main burner tray inside the firebox 9 Lift burner tray away from the main casing 10 D...

Page 18: ...ilot assembly is replaced it must be replaced by an identical unit from the same manufacturer and replaced as a complete unit 1 Carefully remove all coals pebbles and ceramic baseboards 2 Disconnect gas supply 3 Remove 4 screws securing tray to firebox 2 at base of bezel and 2 inside firebox and lift out tray 4 Disconnect the thermocouple from the gas control tap 5 Disconnect the gas connection fr...

Page 19: ... be installed by a Gas safe registered person 2 The appliance must be used in accordance with the users instructions 3 The appliance must be serviced annually by a Gas Safe registered person 4 The service log must be correctly filled out and the record of annual services must be up to date and supported by receipts in each case 5 This warranty is not transferable and relates to the original instal...

Page 20: ...e helpdesk Model UC Living Rosmore Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the appliance flange top right behind trim Retailer Name ___________________________________________ Address ________________________________ __________________________________________ ___________________________________________ Date of Purchas...

Page 21: ...n Fires Date of First annual service Engineer Name Corgi Registration No Date of Second annual service Engineer Name Corgi Registration No Date of Third annual service Engineer Name Corgi Registration No Date of Forth annual service Engineer Name Corgi Registration No Date of Fifth annual service Engineer Name Corgi Registration No We may introduce modifications to products from time to time and c...

Page 22: ...dge which is located on the appliance flange top right behind trim Retailer Name ___________________________________________ Address ________________________________ ___________________________________________ ___________________________________________ Date of Purchase We may introduce modifications to products from time to time and consequently the details given in this booklet are subject to al...

Page 23: ...__________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model UC LIVING ROSMORE Serial No Date of Purchase This information can be found on the label attached to the packaging and on the data badge which is located on the appliance flange top right behind trim WHERE DID YOU PURCHASE THIS PRODUCT Name ________________________________ Address ______________...

Page 24: ...LT Iss 24 Blank Page ...

Page 25: ...LT Iss 25 ...

Page 26: ...LT Iss 26 ...

Page 27: ...LT Iss 27 ...

Page 28: ...age Text Data Badge Fire Box Grommet Burner Tray Box Assembly Warning Label Fire Guard Fuel Bed Comprises of Base Matrix 4720 Bag Of Coals 6543 Front Coal LH 4723 Front Coal RH 4724 Fixing 0705 includes 4 magnets foam seal Restrictor Plate 6549 Owners Book ID Label Packing Labels Serial Number Inspector ...