37754-6-1019
Page 60
MAINTENANCE AND SERVICE (CONT’D)
Glass Cleaning
Clean the glass before use and two or three times each heating
season. During start-up condensation (which is normal) forms
on the inside of the glass and causes lint, dust and other
airborne particles to cling to the glass surface. Also initial paint
curing may deposit a slight film on the glass. Use a non-
abrasive household cleaner and warm water (we recommend
gas fireplace glass cleaner).
General Glass Information
WARNING
Do not operate fireplace with the glass front removed, cracked
or broken.
Only glass approved for use by the manufacturer in fireplace may
be used for replacement. The glass replacement should be done
by a licensed or qualified service person.
WARNING
1. The use of substitute glass will void all product warranties.
2. Care must be taken to avoid breakage of the glass.
3.
Under no circumstances should this fireplace be
operated without the glass front or with a broken glass
front. Replacement of the glass (with gasket) as supplied
by the manufacturer should be done by a qualified
service person.
4. Do not abuse the glass by striking or hitting it.
WARNING
Do not use Ammonia based or abrasive cleaners on glass.
Do not attempt to clean glass when glass is hot.
FOR THE INSTALLER
Maintenance Precautions
Installation and repair should be done by a qualified service
person. The fireplace should be inspected before use and at
least annually by a qualified service person. More frequent
cleaning might be required due to excessive lint from carpeting,
bedding material, etc.
Keep burner and control compartment clean.
Examine venting system periodically and replace damaged parts.
Make a periodic visual check of pilot and burners. Clean and
replace damaged parts.
Damaged Fireplace
Do not use this fireplace if any part has been under water.
Immediately call a qualified service technician to inspect the
fireplace and to replace any part of the control system and any
gas control which has been under water.
In the event of a natural disaster (tornado, earthquake, fire, etc.)
have a qualified technician inspect the fireplace for damage or
potential gas leaks. Repair or replace any damaged components
before operating this fireplace.
Annual Inspection
•
Have the fireplace inspected annually before use.
•
More frequent inspection and cleaning may be required if the
fireplace is installed in an area exposed to pet hair or dust,
or to excessive lint from new carpeting or bedding materials.
During The Annual Checkup, The Technician Will:
•
Inspect the pilot (flame safety system) and burner(s) for
proper operation and replace any damaged parts.
•
Test and measure the flame failure response time of the
flame safety system. It must de-energize the safety shut-off
in no more than 30 seconds.
•
Vacuum and clean any foreign debris in the firebox that is
not supposed to be there.
•
Inspect and ensure that the lighting of the main burner
occurs within 4 seconds of the gas valve opening. Visual
inspection should match the information illustrated in the
manual. Inspect primary air openings for blockage.
•
Check the glass and gasket for proper seal.
•
Clean Glass with a suitable fireplace glass cleaner. Abrasive
cleaners must not be used. Be careful not to scratch the
glass when cleaning.
•
Check all latches or other door retention components for
proper operation, tension, and relief mechanisms are free
from obstructions.
See Figures 66 and 67.
•
Check the barrier screen for fit and structural integrity.
See Figure 68.
•
Inspect the log set (if applicable) and decorative media
(if applicable) for debris or damage.
•
Freshen up the glowing embers if applicable.
•
Replace batteries in the remote transmitter and receiver
if applicable.
•
Inspect the venting and vent termination cap for damage,
corrosion, sooting, or obstruction and correct if present.
•
Check all accessible gas-carrying tubes, connections,
pipes and other components for leaks.
•
In addition, clean and inspect the fireplace following any
remodeling work in your home.