VENTING FIREPLACE (CONT’D)
REMOVE BAFFLE
TO INSTALL
FLUE RESTRICTOR
FLUE RESTRICTOR
Figure 39
WARNING
Use Restrictor for vertically terminated fireplace systems
that are a minimum of 10 feet vertical, and do not include
offsets or horizontal vent runs. Do not use with horizontally
terminated fireplaces.
Figures 37 to 40
show the location and recommended use of the
flue restrictor.
Installation of restrictor before venting is attached.
See Figure 37.
Figure 37
To install the restrictor after the venting is installed, remove
two screws from the end of the flue baffle and set aside. Insert
the restrictor up into the flue collar and position it as shown in
Figures 38 and 39.
Then, re-install the flue baffle.
REMOVE BAFFLE
TO INSTALL
FLUE RESTRICTOR
FLUE RESTRICTOR
Figure 38