6.3
Status lamps / errors
There are a number of errors that the leak detection system monitors. Errors are displayed
as an illuminated lamp on the front or side of the enclosure, the alarm beacon or on the
HMI display screen.
All errors latch and are cleared by the
RESET
button on the front of the enclosure. The
errors are detailed below and, when activated they trigger the red beacon bulb, black
buzzer and line stop (if applicable).
A.
Alarm beacon
: Green for healthy; red for unhealthy/line stop, black audible buzzer for
unhealthy/line stop.
B.
Reset button
to clear latched alarms.
C.
AIR
status bulb. Illuminates when blower or compressed air is off.
D.
Blower status:
The bulb is on when power is supplied to the blower motor. If the power
is interrupted, the bulb doesn't turn on, and the
AIR
status bulb on the enclosure door
turns on.
Software interface description
Reference Manual
July 2022
00809-0100-4245
62
Rosemount CT4215