When packs are compressed the volume inside the pack is temporarily reduced creating
areas of increased pressure inside the package. When these areas of increased pressure
encounter a defect in the pack seal the MAP gas used can escape the package.
The sample bar at the entry/exit of the passive roller head is connected to an air motor in
the CT4215 which continually draws in air from the passive roller head. Any MAP gas
leaking from the package will be drawn into the sample bars and through the leak detector
triggering the counter and product reject systems.
2.9.2
Keg/barrel
The keg/barrel sample head consists of a simple support frame and sample bar that can be
mounted easily onto an existing conveyor line.
A. Support frame.
B. Sample bar.
The sample bar
MUST
be installed < 25 mm (1 inch) above the height of the keg/barrel
being tested allowing the product to pass freely underneath the bar.
If CO
2
is leaking from around the valve on the keg/barrel it will be drawn into the sample
bar and detected by the analyzer.
Equipment and accessories
Reference Manual
July 2022
00809-0100-4245
26
Rosemount CT4215
Summary of Contents for Rosemount CT4215
Page 1: ...Reference Manual 00809 0100 4245 Rev AC July 2022 Rosemount CT4215 Leak Detection System ...
Page 12: ...Contents Reference Manual July 2022 00809 0100 4245 12 Rosemount CT4215 ...
Page 46: ...Start up procedure Reference Manual July 2022 00809 0100 4245 46 Rosemount CT4215 ...
Page 76: ...Software interface description Reference Manual July 2022 00809 0100 4245 76 Rosemount CT4215 ...
Page 86: ...Maintaining the leak detector Reference Manual July 2022 00809 0100 4245 86 Rosemount CT4215 ...