Figure C-4. Rosemount 2140 Field Communicator Menu Tree (Service Tools)
1. Alerts
2. Variables
3. Trends
4. Maintenance
5. Simulate
3. Service Tools
1. Overview
2. Configure
1. Refresh Alerts
2. No Active Alerts
1. Sensor
2. Calibration Frequencies
3. Switch Points
1. Counters
2. Timers
1. Output State
2. Sensor State
3. Sensor Frequency
6. Scaled Variable
(*1)
5. Analog Output
6. Percent of Range
4. Electronics Temperature
5. Terminal Voltage
1. Diagnostics
2. Counts/Times
(*4)
3. Calibrate Sensor
4. Calibrate Analog
5. Partial Proof Test
(*6)
6. Security
7. Locate Device
(*2)
8. Reset/Restore
2. Sensor State
1. Output State
3. Sensor Frequency
4. Scaled Variable (*1)
5. Electronics Temperature
6. Terminal Voltage
(*2)
Only visible if device has a display.
(*4)
Count/Times (HART7) or Count (HART5).
(*3)
Only one option is shown depending on whether
Factory Calibration or Site Calibration is selected.
1. Sensor Frequency
2. Temperature Compensation
3. Uncompensated Frequency
4. Sensor State
5. Sensor Status
1. Dry to Too Dry
2. Dry to Intermediate
3. Wet to Intermediate
4. Wet to Too Wet
5. Zero
1. Sensor Wet Count
2. Reset/Preset Wet Count
3. Calibration Count
4. Fault Count
5. Reset Fault Count
1. Dry Fork Frequency
2. Sensor Frequency
3. Calibrate Dry Fork
4. Sensor Calibration Status
5. Calibration Count
1. Time Since Output Change
2. Total Time Dry
3. Total Time Wet
1. Calibration Temperature
2. Temperature Compensation
3. Process Temperature
1. Sensor Calibration
2. Reset Sensor Calibration
3. Sensor Compensation
1. Output State
3. Restore Factory Calibration
4. Analog Output
5. Percent Range
1. Security Switch Status
2. External Buttons
3. Configuration Buttons
4. HART Lock (*5)
5. LOI Password Protect.
1. Restart Device
2. Load User Defaults
1. Device Lock
2. Lock/Unlock
1. Password Protection
2. Configure Password
1. Restore Factory Calibation
(*3)
2. Restore Site Calibration
(*3)
1. Loop Test
2. Output State
(*5)
3. Sensor State
(*5)
4. Sensor Frequency
(*5)
5. Scaled Variable
(*1)(*5)
6. Electronics Temperature
(*5)
7. Terminal Voltage
(*5)
1. Variable Summary
2. Mapped Variables
3. Device Variables
1. Primary Variable
2. Secondary Variable
3. Tertiary Variable
4. Quaternary Variable
(*1)
Available on a Rosemount 2140 with the
Extended Features Package (EFP).
(*6)
Available on a Rosemount 2140:SIS with the
Extended Features Package (EFP).
(*5)
Available only when operating as a HART
7 device
.
1. Electronics Temperature (Gauge)
2. Status
(*5)
1. Sensor Frequency (Gauge)
2. Status
(*5)
1. Sensor State
2. Status
(*5)
1. Output State
2. Status
(*5)
1. Electronics Temperature (Gauge)
2. Status
(*5)
1. Sensor Frequency (Gauge)
2. Status
(*5)
1. Sensor State
2. Status
(*5)
1. Output State
2. Status
(*5)
1. Terminal Voltage (Gauge)
2. Status
(*5)
1. Scaled Variable (Gauge)
2. Status
(*5)
2. Scaled Variable
1. Scaled Variable (Trend)
3. Status
(*5)
1. Sensor Frequency (Trend)
2. Sensor Frequency
3. Status
(*5)
1. Sensor State (Trend)
2. Sensor State
3. Status
(*5)
1. Output State (Trend)
2. Output State
3. Status
(*5)
1. Electronics Temperature (Trend)
3. Status
(*5)
1. Terminal Voltage (Trend)
3. Status
(*5)
2. Electronics Temperature
2. Terminal Voltage
1. Dry Fork Frequency
2. Wet Fork Frequency
(*1) (*6)
2. Calibrate
Summary of Contents for Rosemount 2140
Page 2: ......
Page 8: ...VI Reference Manual 00809 0100 4140 Rev AA Contents January 2017 Contents ...
Page 14: ...4 Reference Manual 00809 0100 4140 Rev AA Introduction January 2017 Introduction ...
Page 112: ...102 Reference Manual 00809 0100 4140 Rev AA Troubleshooting January 2017 Troubleshooting ...
Page 143: ......