Owner and operator manual
Section 4: Orifice plate installation and removal instructions
3-9008-001 Rev M
January 2015
“Extended time” procedure
93
46.
Open the Bleeder Valve (10B) to vent the Top (14).
Step 46
Step 47 and 48 are ONLY required for Seniors equipped with grease assisted, metal-to-metal
slide valves. Personnel operating the Daniel Senior Orifice Fitting equipped with O-Ring seal
“soft seat” design slide valves skip to step 49.
47.
Remove the stem from the Grease Gun (23) with the Operating Wrench (2) and insert a
Daniel lubricant stick into the Grease Gun (23).