“Quick change” procedure
Section 4: Orifice plate installation and removal instructions
Owner and operator manual
January 2015
3-9008-001 Rev M
10.
Open the Bleeder Valve (10B) with the Operating Wrench (2).
Steps 11 and 12 are ONLY required for the Seniors equipped with grease assisted, metal-to-
metal slide valves. Personnel operating the Senior equipped with O-Ring seal “soft seat” design
slide valves skip to step 13.
11.
Remove the stem from the Grease Gun (23) with the Operating Wrench (2) and insert a
Daniel lubricant stick into the Grease Gun (23).
PRESSURIZED FLUID HAZARD
When opening the bleeder valve (10B) or venting the Top (14) thru the bleeder valve (10B),
direct the released pressurized fluid and/or gas to safe area away from any individual in
accordance with local environment regulations.
The bleeder valve (10B) releases pressurized fluid that may cause contamination and/or
accumulation of volatile gas mixtures. Failure to do so may cause serious injury or death.
The pressure contained in the Top (14) must be lowered to ambient pressure in order to begin
any Orifice Plate (13) procedures. When lowering the pressure in the Top (14), the operator
must direct fluid or gas escaping from the Top (14) to a safe area away from the operator, and in
accordance with local environmental regulations.