Owner and operator manual
Section 4: Orifice plate installation and removal instructions
3-9008-001 Rev M
January 2015
“Extended time” procedure
85
26.
Return the stem to the Grease Gun (23) and begin turning it clockwise by hand into the
Grease Gun (23) until resistance is felt. Once this is done, use the supplied Operating
Wrench (2) to continue to turn the stem at a rate of 4 to 6 turns per minute.
Step 26
PRESSURIZED FLUID HAZARD
Using the Grease Gun (23), inject the grease into the slide valve seat channels at a rate of 4 to 6
turns per minute and only under the following conditions:
• Bleeder Valve is open.
• Sealing Bar/Clamping bar is in place and tight.
Injection of the grease at a faster rate will lead to the separation of the valve strip from the valve
seat, resulting in release of pressurized fluid which may cause serious injury or death.