Section 4: Orifice plate installation and removal instructions
3-9008-001 Rev M
January 2015
“Extended time” procedure
89
35.
Install a new Sealing Bar Gasket (9A, 9A-HP or 9CF) on to the Top (14).
Step 35-36
36.
Install the Sealing Bar (9 or 9HP) and the Clamping Bar (12 or 12HP) on to the Top (14).
37.
Tighten each Clamping Bar Screw (11), located on the Clamping Bar (12 or 12HP), to
the torque recommended in this manual (refer to
Section 5.3: Torque information
EXPLOSION HAZARD
Follow the instructions in this manual to assure that the Sealing Bar Gasket (9A, 9A-HP or 9CF),
the Sealing Bar (9 or 9HP) and the Clamping Bar (12 or 12HP) provide a pressure barrier
between the line pressure and the atmosphere.
Failure to properly install these parts may result in explosive separation of components resulting
in serious injury or death.