Owner and operator manual
Section 4: Orifice plate installation and removal instructions
3-9008-001 Rev M
January 2015
“Extended time” procedure
91
Step 41
Step 42
42.
Rotate the Upper Plate Carrier Shaft (7) located in the Top (14) with the Operating
Wrench (2) in the direction to lower the Orifice Plate Carrier (8DM or 8DMC) into the
Body (4).
43.
Rotate the Lower Plate Carrier Shaft (6) with the Operating Wrench (2) until the Orifice
Plate Carrier (8DM or 8DMC) cannot be lowered further.
Step 43