Owner and operator manual
Section 4: Orifice plate installation and removal instructions
3-9008-001 Rev M
January 2015
“Extended time” procedure
87
Step 28
Step 29
29.
Once the Clamping Bar Screws (11) are loose, it may be necessary to use the Operating
Wrench (2) to tap against the Sealing Bar (9 or 9HP) freeing it from the Top (14).
30.
Slide the Clamping Bar (12 or 12HP) containing the Clamping Bar Screws (11), the
Sealing Bar (9) from the Top (14).
Step 30-31
31.
Remove the Sealing Bar Gasket (9A, 9A-HP or 9CF) from the Top (14).