123
IND100241-31
Appendix
Pinout Assignments
8-pin RJ45 10/100/1000Mbps LAN/Ethernet
1 2 3 4 5 6 7 8
PIN 01
D0P+ Diff erential Pair 0 (Positive)
PIN 02 D0N-
Diff erential Pair 0 (Negative)
PIN 03
D1P+ Diff erential Pair 1 (Positive)
PIN 04
D2P+ Diff erential Pair 2 (Positive)
PIN 05 D2N-
Diff erential Pair 2 (Negative)
PIN 06 D1N-
Diff erential Pair 1 (Negative)
PIN 07
D3P+ Diff erential Pair 3 (Positive)
PIN 08 D3N-
Diff erential Pair 3 (Negative)
Connectors illustrated here are either standard by factory default or may be available (through factory customization).
Note that some combinations may not be possible due to space restrictions. List also valid for customized models. All
pin out assignments are seen from users Point of View (POV) while looking straight at the connector. Please review
the dedicated datasheet or technical drawings for your actual unit to identify and determine the presence of desired
connector. Detailed information about Housing Connectors (terminal blocks) can be found earlier in this manual.
4-pin USB TYPE A
Pin 2: Negative Data
Pin 1: VCC +5V
Pin 3: Positive Data
Pin 4: Ground
2-pin Terminal Block 5.08 - DC Power Input
Pin 2: Negative -
Pin 1: Po
9-pin USB3.0/3.1/3.2 TYPE A
1 2 3 4
9 8 7 6 5
PIN 01
VCC +5V
VBUS / Power
PIN 02 D-
Negative Data
PIN 03
D+
Positive Data
PIN 04 GND
Ground
PIN 05 StdA_SSRX- SuperSpeed Receive Negative Data
PIN 06
St
SuperSpeed Receive Positive Data
PIN 07 GND DRAIN Ground for signal return
PIN 08 StdA_SSTX- SuperSpeed Transmit Negative Data
PIN 09
St
SuperSpeed Transmit Positive Data
Serial COM, 9-pin Non-isolated, DSUB Male
Connector has 3 diff erent modes. Change mode in BIOS.
Advanced > F81846 SuperIO confi guration >
Serial Port 1 Confi guration > F81846 SerialPort1 Mode Select:
RS-232:
1 2 3 4 5
6 7 8 9
PIN 01 DCD
Data Carrier Detect
PIN 02
RxD
Receive Data
PIN 03
TxD
Transmit Data
PIN 04 DTR
Data Terminal Ready
PIN 05 GND
Signal Ground
PIN 06 DSR
Data Set Ready
PIN 07 RTS
Request To Send
PIN 08 CTS
Clear To Send
PIN 09 RI
Ring Indicator
RS-422: Full Duplex Mode*
1 2 3 4 5
6 7 8 9
PIN 01
TxD-
Transmit Data Negative
PIN 02
TxD+
Transmit Data Positive
PIN 03
RxD+
Receive Data Positive
PIN 04
RxD-
Receive Data Negative
PIN 05 GND Signal Ground
PIN 06 N/C
No internal connection
PIN 07 N/C
No internal connection
PIN 08 N/C
No internal connection
PIN 09 N/C
No internal connection
*Master only. ECHO not supported.
RS-485: Half Duplex Mode*
1 2 3 4 5
6 7 8 9
PIN 01 Data- Data Negative
PIN 02
Data+
Data Positive
PIN 03 N/C
No internal connection
PIN 04 N/C
No internal connection
PIN 05 GND Signal Ground
PIN 06 N/C
No internal connection
PIN 07 N/C
No internal connection
PIN 08 N/C
No internal connection
PIN 09 N/C
No internal connection
*ECHO not supported.
Flow control: Via RTS signal (controlled by user application).
Summary of Contents for Hatteland HD 19T22
Page 7: ...7 This page left intentionally blank...
Page 10: ...10 This page left intentionally blank...
Page 11: ...11 General...
Page 21: ...21 Installation...
Page 42: ...42 This page left intentionally blank...
Page 43: ...43 Operation...
Page 46: ...46 This page left intentionally blank...
Page 47: ...47 Specifications...
Page 64: ...64 This page left intentionally blank...
Page 65: ...65 Specifications Accessories...
Page 69: ...69 Technical Drawings...
Page 74: ...74 This page left intentionally blank...
Page 75: ...75 Technical Drawings Accessories...
Page 111: ...111 Appendixes...
Page 140: ...140 Appendix IND100077 24 User Notes...
Page 142: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...