background image

SET

PUB -19750-0999

Page 1 of 4

Specifications

General Information

FT420 Flow Computer
Instructions

The FT420 is a loop-powered microcontroller-based
transmitter/indicator.  It displays rate and total, and pro-
vides a 4-20 mA analog signal proportional to flow.  A
programmable pulse output is also standard for meter-
ing pump control or data logging.

The rugged cast-aluminum housing is gasketed for
maximum environmental protection, and the electron-
ics are potted into a solid block of urethane.  A mem-
brane keypad allows settings to be changed without
removing the cover.  The universal mount version
comes with brackets for wall mounting, and also with
an adaptor for field installation on 80-series flow sen-
sors.  The FT420 can also be factory or field installed
on a TX100/200 series sensor or WT meter.

Power

4 mA DC (4-20 mA loop),
12-32 VDC

Display

Rate

6-digit autorange, 1/2"
charater height

Total

8-digit, 5/16" character
height

Pulse Output

• 0.1 second open collector
pulse (scaled)
• sensor pulse (unscaled)

Input

Pulse fre 5 VDC

K factor Range

0.050 - 2000

Pulse Output Range

0.1 - 200,000 units/pulse

Temperature

0 C - 70 C

Environmental

NEMA 4X

Features

Sturdy gasketed cover

with electronics

potted in

Removeable foot brackets

for wall mounting

Large rate numerals

Easy set-up

prompts

Triple bosses for

watertight input/output

connections

10.5

2341678.9

SET K

RESET

Two wire

4-20 mA output standard

Summary of Contents for FT420

Page 1: ...comes with brackets for wall mounting and also with an adaptor for field installation on 80 series flow sen sors The FT420 can also be factory or field installed on a TX100 200 series sensor or WT meter Power 4 mA DC 4 20 mA loop 12 32 VDC Display Rate 6 digit autorange 1 2 charater height Total 8 digit 5 16 character height Pulse Output 0 1 second open collector pulse scaled sensor pulse unscaled...

Page 2: ...e K factor is the number of pulses per liter that the flow sensor produces To find the K factor on any SeaMetrics flow sensor fitting or in line meter look on the model serial label The line reading K xxxx is the desired number For adjustable sensors 101 201 115 215 look in the instruction manual under your pipe size Set K Begin by pressing the key SET once The prompt SET K should appear on the di...

Page 3: ...1 Sensor Mount Step 2 Sensor Wires Sensor Wires Remove Mounting Feet 3 of 4 TX81 Flow Sensor Pulse Responsive Metering Pump To Other Control 12 30 VDC Loop Power 4 20 mA Output Power 4 20 mA Sensor Pulse Output Sensor Output Red White Black ...

Page 4: ...indicate flow rate and the smaller sized digits indicate total Unless the unit has been ordered with the non reset option a RESET prompt is constantly visible in the lower right corner above the up arrow key Press this key at any time to reset the totalizer to zero FT420 with Wall Mount Brackets 2 06 3 89 3 89 4 31 2 67 2 57 10 5 2341678 9 4 of 4 power supply Chemical FT420 on TX81 Control Pulses ...