P R O G R A M M I N G
_________________________________________________________________________________
GsmAlarm-500
Software ver. 1.15
-
35-
5.7.12.
OUTPUTS C1-C4 (K1, K2): INVERTED MODE AND OPERATING TIME UNITS
The outputs can operate in an inverted mode, i.e., the output circuit is disconnected upon reception of
activation command and connected upon reception of deactivation command.
Manufacturer-programmed value: 04.
In Siren mode the output operating time can be programmed only in minutes. In other modes the
output operating time can be programmed in seconds (if the value is 0) or in minutes.
Manufacturer-programmed value: 00.
Important! To invert several outputs the total of numbers should be used. Example: To invert all
outputs the number to be entered is 15 (1+2+4+8).
5.7.13.
PARAMETER “E”: THE WAY USER IS INFORMED ABOUT ARMING AND
DISARMING
Parameter „E” is described in detail in Chapter 5.3.2.2.
Manufacturer-programmed value: 20.
5.7.14.
PARAMETER “F”: SYSTEM RESPONSE TO INCOMING CALLS AND NUMBER
OF CALLS TO USER
Parameter „F“ defines system response to incoming calls and number of calls to user in alarm state.
It is described in detail in Chapter 5.3.2.5.
Manufacturer-programmed value: 31.
Address
Parameter value
Explanation of operation
320
01
Output C1 inverted.
320
02
Output C2 inverted.
320
04
Output C3 inverted.
320
08
Output C4 (K1, K2) inverted.
Address
Parameter value
Explanation of operation
326
01
Time units of output C1: minutes.
326
02
Time units of output C2: minutes.
326
04
Time units of output C3: minutes.
326
08
Time units of output C4 (K1, K2): minutes.
Address
Parameter
273
System parameter „E“.
Address
Parameter
274
System parameter „F“.