48-
8.1.10.
“ARM”, “SLEEP” and “STAY” INDICATORS
Indicator ARM is alight constantly, if the system is in full arm mode, indicators SLEEP or STAY are
alight constantly, if the system is in partial arm mode. In case of alarm, these indicators flash fast.
8.2.
REGULAR ARMING
This method will arm all the zones in the selected partition. Check to see if the TBL or BYP light is on
before arming the system. Regular arming is possible only if all alarm zones are closed (not triggered).
Constantly alight keypad keys indicate open zones (key [1] – zone Z1, key [10] – zone Z10).
Regular arming:
•
Close all protected doors and windows and stop movement in areas covered by motion
detectors. Check to see that the StayD (Ready) light is on (all zones are closed). The system
cannot be armed till the StayD light is off.
•
Press the [ARM] key.
•
Enter a 4-digit or 6-digit user access code.
As each digit is entered the keypad buzzer will beep. If the security code was entered incorrectly, the
sounder will beep steadily for 2 seconds. If the code was entered correctly but the “Ready” light was not
on, the keypad will beep steadily for 2 seconds. When the correct code is entered, the ARM light will
flash and the keypad buzzer will beep quickly. Exit the premises through the designated exit-entry door.
Exit delay time is indicated by short keypad beeps, repeating each second. At the end of the allowed exit
time the keypad buzzer will beep quickly and the ARM light stays on constantly. User receives
confirmation short call or SMS message (depends on system configuration, see Ch. 5.3.2.2).
If system is divided into two partitions, only one partition or both partitions at once can be armed when
using particular access code. Functionality of the access codes is described in Chapter 5.7.2.
Regular arming can also be activated using 24-hour timer or One-Touch arming. One touch arming
allows you to arm the system without using access codes. Press and hold the [ARM] key for 3 seconds to
arm the system.
8.3.
STAY & SLEEP ARMING
Stay arming method allows you to roam freely within the premises while the perimeter is fully armed.
Stay zones are zones that are bypassed when Stay arming. For example, if you plan on staying in for the
night, doors and windows can be armed without arming other zones like motion detectors.
Stay arming:
•
Close all zones in the desired partition (except Stay zones).
•
Press the [STAY] key.
•
Enter a 4-digit or 6-digit user access code.
Similar to Stay arming, Sleep arming allows users to remain in a protected area, but provides a higher
level of protection. For example, in a two-story house, the perimeter is protected with Stay arming. With
Sleep arming, the perimeter as well as the main floor are protected (motion detectors, etc.), allowing you
to roam the second floor and sleeping quarters. Sleep zone are zones that are bypassed when Sleep
arming. For example, when you go to sleep at night, the entire premises except your bedroom is fully
armed.
Sleep arming:
•
Close all zones in the desired partition (except Sleep zones).
•
Press the [SLEEP] key.
•
Enter a 4-digit or 6-digit user access code.
Stay and Sleep arming can also be activated using 24-hour timer or One-Touch arming. Press and hold