background image

P R O G R A M M I N G  

 

 

_________________________________________________________________________________ 
GsmAlarm-500                                                  

                                                          

Software ver. 1.15 

                                                                              -

40- 

5.9.

 

PROGRAMMING AND DIAGNOSTICS OVER THE INTERNET  

 
The system parameters may be changed and the system status may be observed by connecting over 
the internet. The data are transmitted according to TCP/IP protocol; the GSM module connects to the 
internet  via  a  GPRS  cannel.    The  connection  is  established  by  the  GSM  alarm  configuration  tool 
GAprog. The application is downloadable from the website of the manufacturer at 

www.eltech.lt

 
Two conditions are necessary for connection over the internet. 
  
The  first  condition:  GPRS  service should  be activated  for  the  SIM  card  of the  GSM  module. 
Usually,  GPRS  service  is  activated  automatically.  You  may  contact  your GSM  service  provider  to 
inquire about activation of the GPRS service.  
  
The  second  condition:  The  GSM  module  or  the  computer  that  is  used  for  connection  to  the 
GSM module should have unique IP addresses.
 A unique IP address also is called a real address or 
an external address. An external IP address is accessible from any internet-connected computer. An 
IP address is automatically provided to the GSM module  by the GSM network. Inquire your GSM 
service provider to find out, if your SIM card has a unique IP address. Inquire your ISP to find out, if 
your computer has a unique IP address. 
 
Before  connecting  to  the  module,  it  is  recommended  to  verify  access  point  settings.  Send  the 
following SMS message to GsmAlarm-500: 
 

   or        

(if SMS password is deactivated )               

                                             

 
The massage returned to the user by GsmAlarm-500 contains the access point name, the login name 
and the login password: 
 

AAAAAAAA APN:internet.tele2.lt, APLOG:wap, APPASS:wap, 

 
Adjust  the  access  point  name,  the  login  name  and  the  login  password  as  required.  In  Lithuanian 
networks OMNITEL and BITE GSM, all fields may be blank (comma after colon). The access point 
name  of  TELE2  network  is      internet.tele2.lt  ,  other  field  may  be  blank.  The  SMS  message  with 
adjustments is sent back to the GsmAlarm-500 module. 
 
There are two ways to connect to a GsmAlarm-500 module over the internet. 
  
The first method: the user connects to the GSM module (the module operates as a server).  This 
method is possible only if the GSM network has assigned an unique IP address to the module. The 
user sends an SMS message to the GSM module: 
 

 

 or 
                                                                   

 (if SMS password is deactivated) 

 
The  GETIPA  command  activates  the  GPRS  interface  of  the  GSM  module  and  the  “server”  mode.  
The GSM module  sends connection data  to  the user: the  IP  address  and the port number.  The user 
should mark the option “Connect to GSM module” in the window “Connect over GPRS”, enter the IP 
address and the port number, click the button “Connect”, and wait for establishment of connection. 
 
The  second  method:  the  GSM  module  connects  to  the  computer  of  the  user  (the  module 
operates as a client). 
 This method is possible only if a real (unique) IP address has been assigned to 

A A  A A  A A A  A   A P  N 

A  P  N 

A A  A A  A A A  A   G E  T  I  P  A 

G E  T  I  P  A 

Summary of Contents for GsmAlarm-500

Page 1: ...e performed from any computer or smart phone using a standard web browser Possibility to send information to alarm monitoring station using the Contact ID protocol through GSM voice call Remote contro...

Page 2: ...nsors 12 5 Programming 13 5 1 General Programming Instructions 13 5 2 User and Alarm Monitoring Station numbers 13 5 2 1 Programming with Standard Mobile Phone 14 5 2 2 Programming with SMS 14 5 3 Pro...

Page 3: ...g Calls and Number of Calls in Alarm State 35 5 7 15 Parameter G Delay Time of Report SMS about the Power Supply Failure 36 5 7 16 Parameter H Data Transfer to the Alarm Monitoring Station 36 5 7 17 P...

Page 4: ...dicator 47 8 1 10 ARM SLEEP and STAY Indicators 48 8 2 Regular Arming 48 8 3 Stay Sleep arming 48 8 4 Disarming Deactivating an Alarm 49 8 5 Panic Alarms 49 8 6 Control of Separate Partitions 49 8 7 P...

Page 5: ...nside installation room with automatic 2 pole circuit breaker capable of disconnecting circuit in the event of short circuit or over current Open circuit breaker must have a gap between connections of...

Page 6: ...ant to moisture chemical materials or mechanical damage Don t attempt to personally repair the system System label is on the top side of the device This symbol on the product or on its packaging means...

Page 7: ...mine protected unit state system mode etc The system is controlled by iButton also known as DALLAS keys Several control functions can be assigned to each key Example a user can activate a protection m...

Page 8: ...ors KTY81 110 PHILIPS The zones are designed to work with End of Line EOL resistors of 2 2k and 4 7k in ATZ mode see Ch 4 2 4 The system becomes triggered both when the input circuit is broken as well...

Page 9: ...Ch 5 3 2 1 Equivalent diagram of C output 2 5 BELL SIREN CONNECTION TERMINALS K1 and K2 These terminals are relay contacts of the programmable output C4 K1 and K2 are used to connect audio siren or ex...

Page 10: ...is being sent Blinks 5 times short break after Very good signal Blinks 4 times short break after Good signal Blinks 3 times short break after Satisfactory connection Blinks 2 times short break after...

Page 11: ...in metal housing 7TRP20 as recommended Housing fixture holes 4x5mm SAUGIKLIS Metal housing 7 TRP20 RED BLUE POWER SUPPLY TRANSFORMER T 0 16A LSTEN 60950 TRP 20 01 BACKUP BATTERY AC 12V 1 3Ah CT1 3 12...

Page 12: ...status LED indicator woks in sync with the MODE indicator see Ch 3 2 The state of this indicator allows identification of the alarm system status and verification of closure of all protected zones be...

Page 13: ...BLUE 1k GREEN YELLOW BLACK BLUE Keypad No 2 RED 1k Keypad zone 2 Power supply for motion or fire detectors K1 K2 Siren 4 7k 2 wire smoke detector EA318 2 AC 230V 0 16A Fuse 5 2 4 2 2 SYSTEM WITH iBUTT...

Page 14: ...ply transformer and the backup battery are connected according to the wiring diagram of the premise security system see Ch 4 1 The gate control system operating output C4 is connected to terminals K1...

Page 15: ...s 6 inputs Z1 Z6 corresponding to the zone numbers Z01 Z06 If 6 zones are sufficient for protection of the object the wiring diagrams 1 2 3 or 4 may be deployed Load resistors are mounted in the housi...

Page 16: ...be programmed only in 0 99 C range The temperature difference at which triggered zone returns to primary state hysteresis complies with the parameter I see Ch 5 3 1 In temperature measurement mode in...

Page 17: ...block of GsmAlarm 500 device The parameters of the system can be programmed by sending SMS message see Ch 5 3 or by using Paradox keypad see Ch 5 7 It is recommended to change the SMS password at the...

Page 18: ...station Important It s important to note that while programming SIM card memory should be active not phone memory Otherwise the user number will be recorded in the mobile phone memory used for program...

Page 19: ...to receive SMS with programmed numbers ALRNR1 ALRNR5 send GsmAlarm 500 the following SMS A A A A A A A A N R I N F O Extra user numbers only for gate control are programmed by sending the following SM...

Page 20: ...d output operating modes delay times and names can be programmed with the help of SMS First it is recommended to receive SMS with programmed parameters and then to send the same SMS with corrected par...

Page 21: ...onds Minimal time 10 seconds 1 maximal time 90 seconds 9 The factory preset time 20 seconds If N 0 or N 1 the pulse counting mode is switched off In temperature measuring mode parameter I complies hys...

Page 22: ...ired if tamper recognition is on see Ch 5 3 1 3 4 4 Follow zone 6 2 wire smoke detector connected to the PGM output C3 1 5 5 Double acting delay zone 7 ATZ mode with tamper recognition Triggers when c...

Page 23: ...n the zone is restored contacts return to initial state the system does not call and does not turn on the siren In this case users only receives an SMS message if SMS message sending is activated see...

Page 24: ...ystem parameters send GsmAlarm 500 the following SMS A A A A A A A A C P A R A M Receiving the message is confirmed by blinking of indicator MODE SMS with current system parameters is being sent AAAAA...

Page 25: ...onset time J02 detection of GSM jamming signal activates the siren J03 operates as the functions J01 and J02 K00 the method of system control K00 the system is controlled by a PARADOX keypad K01 the s...

Page 26: ...hort call number coincides with programmed numbers M06 Siren mode M07 Siren mode with audible confirmation After arming one short audible beep is heard After disarming two short audible beeps are hear...

Page 27: ...ren mode the output operating time can be programmed only in minutes 5 3 2 3 CONFIGURATION OF THE GATE CONTROL MODE Connect the system after the wiring diagram presented in Chapter 4 2 3 The message A...

Page 28: ...f a call is received from unknown caller user ALRNR1 will receive a SMS with caller s number 1 1 After alarm triggering users are called once If calling from user s number after 3 4 calls the system w...

Page 29: ...nt to all users ALARNR1 ALARNR5 Manufacturer programmed value L32 Important To activate several functions the total of numbers should be used Example To activate all three functions the digit X should...

Page 30: ...year month day GsmAlarm 500 sends back SMS with programmed system time to the specific user 5 3 5 PROGRAMMING 24 HOUR TIMER Timer function can activate or deactivate the programmable output arm or dis...

Page 31: ...tput C2 33 Activates output C3 30 Deactivates output C3 44 Activates output C4 K1 K2 40 Deactivates output C4 K1 K2 77 Requests to send SMS message with information about output state 80 Disarms the f...

Page 32: ...sage is sent to GsmAlarm 500 to receive an SMS message with the user names A A A A A A A A U P A R A M GsmAlarm 500 sends 3 messages with user names to the user AAAAAAAA U01 User1 U02 User2 U03 User3...

Page 33: ...15 Zone operating mode entry delay or triggering temperature T Z01 Z15 133 Delay time of report SMS about the failure of main power supply G S01 141 144 Output operating mode operating time T C01 C04...

Page 34: ...ts ARM and STAY will lit constantly Enter a new 4 or 6 digit access code To delete an Access Code Press the ENTER key Enter your system installer code default code is 0000 or 000000 Select a user by e...

Page 35: ...r access code functionality 035 5 user access code functionality 036 6 user access code functionality 037 7 user access code functionality 038 8 user access code functionality 039 9 user access code f...

Page 36: ...riggered It is described in detail in Chapter 5 3 1 2 Manufacturer programmed values for all zones 70 Address Parameter 101 Zone Z1 T parameter 102 Zone Z2 T parameter 103 Zone Z3 T parameter 104 Zone...

Page 37: ...al time 10 seconds 1 maximal time 90 seconds 9 If Ni 0 or Ni 1 the pulse counting mode is switched off In temperature measuring mode this parameter comply temperature difference at which triggered zon...

Page 38: ...utput C3 144 Operation time of output C4 K1 K2 In siren mode operation time is in minutes in all other modes in seconds or in minutes Manufacturer programmed time C1 00 sec C2 05 sec C3 00 sec C4 K1 K...

Page 39: ...ts the number to be entered is 15 1 2 4 8 5 7 13 PARAMETER E THE WAY USER IS INFORMED ABOUT ARMING AND DISARMING Parameter E is described in detail in Chapter 5 3 2 2 Manufacturer programmed value 20...

Page 40: ...SYSTEM RESPONSE TO INTENTIONAL GSM JAMMING Parameter J defines the system response to intentional GSM jamming Manufacturer programmed value 01 5 7 18 PARAMETER L SMS STRUCTURE AND SMS PASSWORD FUNCTIO...

Page 41: ...r K32LCD keypad is used keypad zone is selected by pressing two digits For example if you want to assign zone 16 to the keypad zone press 1 and 6 If you want to assign zone 3 press 0 and 3 Keypad zone...

Page 42: ...cating event number The lights ARM and STAY will lit constantly Enter 6 digit event instruction and event time First two digits event instruction where following four timer activation time E g for out...

Page 43: ...ws programming deletion and assigning of iButton keys to a specific user or programmable output and setting up of key control functions The GSM alarm configuration tool is downloadable from the websit...

Page 44: ...module it is recommended to verify access point settings Send the following SMS message to GsmAlarm 500 or if SMS password is deactivated The massage returned to the user by GsmAlarm 500 contains the...

Page 45: ...RS enter the port number click the button Wait and wait for the GSM module to connect to the computer The GSM module retries connecting to the specified IP address every 30 seconds The computer IP add...

Page 46: ...e5 205 A30 245 M70 285 P10 335 I02 105 T00 Z6 Zone6 206 A30 246 M70 286 P10 336 I02 106 T00 Z7 Zone7 207 A52 247 M70 287 P10 337 I02 107 T00 Z8 Zone8 208 A00 248 M70 288 P10 338 I02 108 T00 Z9 Zone9 2...

Page 47: ...he LED of security system keypad will indicate a connection problem fault Once the system will get a response from the monitoring station the LED indicator will go off in this case a test message will...

Page 48: ...C 1 2 3 4 AAAAAAAA SMS password CIDACC programming command 1234 four digit user account number Important a no characters or spaces can be used before the password b no spaces are allowed before and a...

Page 49: ...receive information about the object only after sending appropriate SMS message or after calling to GsmAlarm 500 number and entering appropriate DTMF code If H value is H11 or H12 GsmAlarm 500 is oper...

Page 50: ...s case Z11 zone is corresponded by key 1 Z12 key 2 Z15 key 5 Extended indication mode is switched off after pressing once again or after pressing CLEAR 8 1 2 TBL KEY TROUBLE DISPLAY If key TBL illumin...

Page 51: ...made so that the panel can be armed To bypass zones press BYP key and enter 4 or 6 digit user access code BYP key starts to flash Zone can be bypassed by pressing key indicating certain zone number C...

Page 52: ...tly User receives confirmation short call or SMS message depends on system configuration see Ch 5 3 2 2 If system is divided into two partitions only one partition or both partitions at once can be ar...

Page 53: ...vated or deactivated together 8 7 PROGRAMMABLE OUTPUT CONTROL The programmable output PGM on the GsmAlarm 500 can be made to activate by a command from the keypad This output can be used for operating...

Page 54: ...f system is divided into two partitions names of protected objects partitions can be seen in the SMS message OBJECT 1 SYSTEM ARMED SLEEP MODE USER1 OBJECT 2 SYSTEM DISARMED USER2 System can be configu...

Page 55: ...s armed or disarmed While answering user hears what is happening in the premises and also can control system by by entering 2 digit codes using his phone keypad For example after entering code 99 the...

Page 56: ...as capability to detect intentional jamming of GSM If the detection function is on see Ch 5 3 2 or 5 7 17 the siren is activated upon detection of the jamming signal and the user is informed thereof b...

Page 57: ...ivates output C1 10 Deactivates output C1 22 Activates output C2 20 Deactivates output C2 33 Activates output C3 30 Deactivates output C3 44 Activates output C4 K1 K2 40 Deactivates output C4 K1 K2 77...

Page 58: ...ontrolled by this number for gate or fence control ADDNR C2 Additional user number programming instruction Only the output C2 is controlled by this number for gate or fence control ADDNR C3 Additional...

Page 59: ...PRS settings MSTID User ID programming for monitoring station server GPRS channel MSTIP IP address programming for monitoring station server MSTPR Port programming for monitoring station server SCON S...

Page 60: ...blank Save data into the device Create an account on web page sc eltech lt Once you have an account register one or more GsmAlarm devices Create your own device name Device identification number and...

Page 61: ...on purpose mechanical chemical electric damage and in other cases that are not related with GsmAlarm 500 manufacturing defects are seen If security system is not operating properly or breaks down for...

Page 62: ...tive state Closed contacts Non active state Open contacts PROGRAMMABLE OUTPUTS C1 C2 C3 Output type Open collector Maximum current 150 mA max Output active Connected to GND Output non active Open cont...

Page 63: ...MOUTING HOLES _________________________________________________________________________________ GsmAlarm 500 Software ver 1 15 59...

Reviews: