OUTPUTS C1-C4 (K1, K2): OPERATING MODE
Addr:[321-325]
Output
mode
Explanation of operating
M00
M01
Output controlled by DTMF or SMS instructions.
If zero operating time is programmed (T00), output is activated/deactivated and
remains in the same state after receiving DTMF or SMS instruction.
If not zero operating time is programmed, after receiving DTMF or SMS
instruction, output is activated, it deactivates automatically after expiration of the
programmed time.
M02
System state indicator mode. Output is in operating together with MODE indicator.
M03
Output is activated when the system is armed. It is deactivated when the system is
disarmed. If the system is divided into two partitions, the output C1 indicates a
state of the firs partition, the output C2 indicates a state of the second partition.
M04
Control by short call without number recognition function. Output is activated with
a call from any number. If zero operating time is programmed (T00), output state
changes after a call and remains unchanged till the next short call.
If not zero operating time is programmed, after receiving short call instruction
output is activated, it deactivates automatically after expiration of the programmed
period.
M05
Control by short call with number recognition function (gate control mode). This
mode operates analogue to M04, thus it is activated only if short call number
coincides with programmed numbers.
M06
Siren mode.
M07
Siren mode with audible confirmation. After arming, one short audible beep is
heard. After disarming, two short audible beeps are heard.
M08
Output is activated in case of wiring trouble of fire sensor.
M09
Output is activated in case of AC mains failure.
M10
Output is activated in case of GSM signal loss.
M30
Additional audible buzzer mode.
M11
Output state depends on the state of zone Z1 *
M12
Output state depends on the state of zone Z2 *
M13
Output state depends on the state of zone Z3 *
M14
Output state depends on the state of zone Z4 *
M15
Output state depends on the state of zone Z5 *
M16
Output state depends on the state of zone Z6 *
M17
Output state depends on the state of zone Z7 *
M18
Output state depends on the state of zone Z8 *
M19
Output state depends on the state of zone Z9 *
M20
Output state depends on the state of zone Z10 *
M21
Output state depends on the state of zone Z11 *
M22
Output state depends on the state of zone Z12 *
M23
Output state depends on the state of zone Z13 *
M24
Output state depends on the state of zone Z14 *
M25
Output state depends on the state of zone Z15 *
M30
Additional audible buzzer mode.
M31
The output is activated by simultaneously pressing and holding ENTER and
CLEAR keys for 3 sec. This mode is recommended for switching of power supply
voltage of fire sensors. Conditions of mode M01 (M00) also persist.
M32
The output is activated by simultaneously pressing and holding the keypad buttons
1 and 2 for 3 sec or by the command “Logical Key 1”. **
The output is deactivated by simultaneously pressing and holding the keypad
buttons 2 and 3 for 3 sec or by the command “Logical Key 4”. **