P R O G R A M M I N G
_________________________________________________________________________________
GsmAlarm-500
Software ver. 1.15
-
20-
5.3.1.3.
PARAMETER “P” PARTITION ASSIGNMENT AND PARTIAL ARM METHODS:
STAY, SLEEP, TAMPER RECOGNITION Addr: [281-296]
Partition assignment
PXY
Partial arming mode STAY and SLEEP.
Tamper recognition.
X
Y
-
-
0
All functions listed below are disabled.
Zone assigned to the first partition.
1
1
Zone is active in STAY mode and in full
protection mode.
Zone assigned to the second partition.
2
2
Zone is active in SLEEP mode and in
full protection mode.
Zone assigned to both partitions.
3
4
Tamper recognition is enabled.
Manufacturer-programmed value: P10.
Important ! The sum of corresponding digits should be used to activate several Y functions.
Example: the number Y must be 7 (1+2+4=7) to activate all functions.
5.3.2.
PROGRAMMING OUTPUTS C1-C4 (K1, K2) AND COMMON SYSTEM
PARAMETERS “E”, “F”, “G”, “H”, “J”, “K”, “L”, “P”, “T”
In order to receive SMS with output and common system parameters, send GsmAlarm-500 the
following SMS:
A A A A A A A A C P A R A M
Receiving the message is confirmed by blinking of indicator “MODE”, SMS with current system
parameters is being sent:
AAAAAAAA C1:M01T00V00 OutC1, C2:M05T05V00 OutC2, C3:M31T05V01 OutC3,
C4:M06T02V00 Siren, S01:E20F31G01H00J00K00L32P00T20
C1 - number of the programmable output. C4 corresponds to siren connection terminals K1, K2.
M01 - output operating mode (see Ch. 5.3.2.1).
T00 - output operating time. Outputs C1-C3: in seconds, C4 (K1, K2): in minutes.
V00 - output operating time units (minutes/seconds) and operating mode (see Ch. 5.3.2.2).
OutC1, OutC2, OutC3 and Siren - programmable output names. User can change the name under
his own discretion. Maximum number of name characters: 16.
S01: - command for common system parameters programming.
E20 - the way to inform user about arming/disarming. User can be informed by short call or SMS
message. (see Ch. 5.3.2.2) .
F31 - system response to incoming/outgoing calls and number of calls in alarm state. (see Ch.
5.3.2.5).
G01 - SMS delay time in case of the main power supply failure (see Ch. 5.3.2.6).
H00 - modes of data transfer to the alarm monitoring station. (see Ch. 7.3).