P R O G R A M M I N G
_________________________________________________________________________________
GsmAlarm-500
Software ver. 1.15
-
34-
5.7.9.
ZONE RESPONSE TIME
This parameter indicates the duration of presence of a constant signal at the input that is required for
the system to register an alteration of the zone status. The system becomes increasingly resistant to
interference with increase of this time. The set time should be multiplied by 100 to obtain the time in
milliseconds. The range of possible values: 01-99 x100 ms (0.1 s – 9.9 s).
The factory default values for all zones: 05 (500ms).
5.7.10.
OPERATING TIME OF OUTPUTS C1-C4 (K1, K2)
Output operating time (if output operates in impulse mode). Possible values: 00-99.
Address
Parameter
141
Operation time of output C1.
142
Operation time of output C2.
143
Operation time of output C3.
144
Operation time of output C4 (K1, K2).
In siren mode operation time is in minutes, in all other modes in seconds or in minutes.
Manufacturer-programmed time: C1:00 sec., C2:05 sec., C3:00 sec., C4 (K1, K2): 02 min.
5.7.11.
OPERATING MODE OF OUTPUTS C1-C4 and BELL
Possible operating modes are described in detail in Chapter 5.3.2.1.
Address
Parameter
321
Operating mode of output C1.
322
Operating mode of output C2.
323
Operating mode of output C3.
324
Operating mode of output C4.
Manufacturer-programmed output modes: C1:01, C2:05, C3:31, C4:06.
Address
Parameter
151
Response time of zone Z1
152
Response time of zone Z2
153
Response time of zone Z3
154
Response time of zone Z4
155
Response time of zone Z5
156
Response time of zone Z6
157
Response time of zone Z7
158
Response time of zone Z8
Address
Parameter
159
Response time of zone Z9
160
Response time of zone Z10
161
Response time of zone Z11
162
Response time of zone Z12
163
Response time of zone Z13
164
Response time of zone Z14
165
Response time of zone Z15