P R O G R A M M I N G
_________________________________________________________________________________
GsmAlarm-500
Software ver. 1.15
-
19-
5) ON/OFF zone. This mode is intended to arm or disarm the system by the switch. If the system is
divided into two partitions, controlling partition is selected by parameter P (see.Ch. 5.3.1.3).
6) Follow zone. Violation of the zone activates alarm immediately if another zone with delay is not
violated. If a zone with delay is triggered at first (e.g. a door is opened), "follow" zone gets the delay
time of the zone violated before. This mode is recommended for the motion sensor area where the
sensor is installed at the entrance door.
7) In double-acting mode, the system responds to both – to the zone triggering and to restore. When
the zone is triggered, the system works the same as in modes 0 or 1. When the zone is restored
(contacts return to initial state), the system does not call and does not turn on the siren. In this case
users only receives an SMS message (if SMS message sending is activated; see. Ch. 5.3.1.2).
5.3.1.2.
PARAMETER “M”: SYSTEM STATE AFTER INPUT TRIGGERING
Addr: [241-256]
Type of alarm after input triggering
M
XY
Users, getting information about zone
violation
X
Y
All functions, described below, are
deactivated.
0
0
All (ALRNR1-ALRNR5).
Only siren is operating.
1
1
Only user ALRNR1.
System is calling.
2
2
Only user ALRNR2.
Siren and calling.
3
3
Only user ALRNR3.
System is sending SMS message.
4
4
Only user ALRNR4.
Siren and SMS.
5
5
Only user ALRNR5.
Calling and SMS.
6
6
Users ALRNR1 and ALRNR2.
Siren, calling and SMS.
7
7
Users ALRNR1, ALRNR2 and
ALRNR3.
-
-
8
Users ALRNR1, ALRNR2, ALRNR3
and ALRNR4.
-
-
9
All (ALRNR1-ALRNR5), but not the
alarm monitoring station.
Important: alarm monitoring station is informed when data transfer to monitoring station is turned
on (see Ch. 7.3), number X is higher than 0 and number Y isn’t equal to 9.