P R O G R A M M I N G
_________________________________________________________________________________
GsmAlarm-500
Software ver. 1.15
-
44-
If data encryption is used, the encryption key can be entered using GAprog program. GsmAlarm-500
supports AES128 encryption algorithm.
GPRS access point settings can be received at GSM service operator. In most cases, all access point
settings can be left blank.
7.2
AUDIO CHANNEL SETTINGS
Alarm monitoring station telephone number (numbers) is (are) provided by security service that
protects particular object. Telephone numbers are programmed in the same way as user numbers (see
Ch. 5.2.1 and 5.2.2). In most case one number CIDNR1 is sufficient. It is recommended to program
with international code (+370...).
7.2.1.
PROGRAMMING CONTACT ID USER ACCOUNT NUMBER
Four digit user account number is provided by security service that protects object. Programming can
be performed with keypad (see Ch. 5.7.25) or with SMS message.
In order to program the account number, following SMS is sent:
A A A A A A A A C I D A C C : 1 2 3 4
AAAAAAAA - SMS password;
CIDACC: - programming command;
1234 - four digit user account number.
Important:
a)
no characters or spaces can be used before the password;
b)
no spaces are allowed before and after the colon;
If number programming command was performed successfully, the user receives SMS with
programmed identification number.
In order to get programmed account number following SMS message is sent:
7.3.
MODES OF DATA TRANSFER TO THE MONITORING STATION Addr:[233]
Modes of data transfer to the alarm monitoring station are determined by general system parameter
H. H parameter can be programmed with SMS message (see Ch. 5.3.2) or with keypad (see Ch.
5.7.16). Possible values are presented in the table.
Information is received by users
ALRNR1 - ALRNR5.
H
XY
Information is received by alarm monitoring
station.
X
Y
Users doesn‘t get information about
protected object.
0
0
Data transfer to alarm monitoring station is off.
Users are informed about all events
with SMS messages.
1
1
Partial data transfer via audio channel in on.
Data about violation of protected zone, power
supply fault, malfunction of the backup battery,
malfunction of the fire zone, is transferred.
Periodical test signal can be sent.*
A A A A A A A A C I D A C C